- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Control System Instrumentation.ppt
* Chapter 9 Control System Instrumentation Figure 9.3 A typical process transducer. Transducers and Transmitters Figure 9.3 illustrates the general configuration of a measurement transducer; it typically consists of a sensing element combined with a driving element (transmitter). Transducers for process measurements convert the magnitude of a process variable (e.g., flow rate, pressure, temperature, level, or concentration) into a signal that can be sent directly to the controller. The sensing element is required to convert the measured quantity, that is, the process variable, into some quantity more appropriate for mechanical or electrical processing within the transducer. Standard Instrumentation Signal Levels Before 1960, instrumentation in the process industries utilized pneumatic (air pressure) signals to transmit measurement and control information almost exclusively. These devices make use of mechanical force-balance elements to generate signals in the range of 3 to 15 psig, an industry standard. Since about 1960, electronic instrumentation has come into widespread use. Sensors The book briefly discusses commonly used sensors for the most important process variables. (See text.) Transmitters A transmitter usually converts the sensor output to a signal level appropriate for input to a controller, such as 4 to 20 mA. Transmitters are generally designed to be direct acting. In addition, most commercial transmitters have an adjustable input range (or span). For example, a temperature transmitter might be adjusted so that the input range of a platinum resistance element (the sensor) is 50 to 150 °C. In this case, the following correspondence is obtained: 20 mA 150 °C 4 mA 50 °C Output Input This instrument (transducer) has a lower limit or zero of 50 °C and a range or span of 100 °C. For the temperature transmitter discussed above, the relation between transducer output and input is The gain of the measurement element Km is 0.16 mA/°C. For any linear instru
您可能关注的文档
最近下载
- 20世纪人类最伟大的100项科学发明.doc VIP
- 刘诗诗资料.doc VIP
- 喜剧的十三种结构.pdf VIP
- 2025年闽教版(2024)小学英语四年级上册(全册)教学设计(附目录P123).docx
- 人教版高中英语第三册Unit 1 FESTIVALS AND CELEBRATIONS教学设计.docx VIP
- 数据结构常用算法数据结构算法.pdf VIP
- 北师大版九年级上册数学第一次月考试卷及答案.docx VIP
- 2025年最新版个人征信报告(含水印)模板【可修改】 .pdf VIP
- 金刚砂地坪施工技术交底.pdf VIP
- 人教版英语2024七年级上册全册单元知识清单(背诵版).pdf VIP
文档评论(0)