* 12/13/96 31 Intro-1 (= Transparency 19) We need to know temperature to compensate for its affect on the elasticity and rigidity of the metal flow tubes, which determine how the tubes responds specifically to flow and density. We’ll discuss that again later. The temperature indicated by the RTD also represents the temperature of the process with considerable accuracy. In current Micro Motion sensor design, the RTD temperature is equivalent to a thermowell sensor in terms of indicating process temperature. * 12/13/96 4 Intro-1 (= Transparency 2) Note: TX-2 depicts a system based on the RFT9739