倒母线注意事项(国外英文资料)

倒母线注意事项 One, 220kV bus connection mode 220kV bus lines are commonly used for wiring of double bus, double bus, mother-sister switch, and single bus cable. 220kV bus lines are recently planned to use double bus single-section wiring, and forward planning USES double bus double section wiring. Double busbar single segment connection in addition to have a reliable power supply, flexible scheduling, expansion of convenient advantages, a double busbar with bypass bus connection and the advantages of simple manipulation, so now the newly built 220 kv bus bar mainly adopts double busbar single (double) segmented wiring. Second, 220kv double bus line control sequence optimization and danger point (1) the order and danger points of the mother-difference interconnection, the mother-link change non-automatic, and the TV secondary Bus interconnection has two functions: (1) when two bus knife switches on stage at the same time, two points difference of poor mother loop current is not balanced, not work properly, but 2 total busbar differential current is balanced, so we must change a single mother, using total differential protection; (2) after the bus coupler circuit breaker non-automatic instead, if a single mother, any one is double busbar busbar fault Os trip, if you dont change a single mother, after any bus fault is to start the bus malfunction, jumped the fault busbar, resection (0.2 s) delay long time, adverse to the system security. The mother link is not automatic: when the bus is hot, the female line is closed and then pulled, and if the mother union jumps open, it will cause the load to pull the blade. TV secondary coordinate function: when the 2 bus and closed at the same time, the breaker switch relay action at the same time, also will automatically TV twice, but switching relay contact capacity is small, secondary circulation TV may harm it, so the manual will be TV secondary, USES a large capacity contact. If mother will switch to the automatic, first into diffe

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档