电磁炉维修方法)(国外英文资料)
电磁炉维修方法)
Simple maintenance method of electromagnetic oven circuit board
First, the circuit board burning IGBT or fuse maintenance procedures
The current fuse or IGBT is burned out and cannot be replaced immediately. It must be confirmed that the following parts will be replaced in normal condition, otherwise the IGBT and fuse will burn out.
1. whether the visual current fuse is blown or not
2. check if IGBT is broken:
Use a multimeter diode to measure the E of the IGBT; C; and G between the three poles.
A: E is extremely close to G; C is extremely G, and both positive and negative tests are not normal (normal).
B: multimeter, red pen, E, extremely, black pen, C, there are about 0.4V voltage drop (model GT40T101, three poles completely blocked).
3. measuring whether the transformer is broken or not, the normal state is as follows:
The resistance of the instrument transformer is approximately 80 ohms by using a multimeter, and the initial pole is 0 ohms.
4. is the rectifier bridge normal (tested with a multimeter diode mount)?:
A: multimeter, red pen, -, black pen +, there is about 0.9V voltage drop, tone counter, no display.
B: multimeter, red pen, -, black pen, respectively, two input, there are about 0.5V voltage drop, the tune is not displayed.
C: multimeter, black pen, +, red pen, respectively, two input, there are about 0.5V voltage drop, tone, no display.
5. check the capacitor C301; C302; C303; whether the heat damage. (if the damage has been deformed or burned)
6. test chip 8316 whether breakdown:
Methods of measurement: use a multimeter to measure 8316 pins, requiring 1 and 2; 1 and 4; 7 and 2; 7 and 4 cannot be shorted.
Is the thermal switch insulation protection damaged at 7.IGBT?. Key action detection, measuring whether the CPU line breakdown:
Two, the key action is not good
With a multimeter measuring deflection diode CPU pole and earthing terminal voltage were about 0.7V, multimeter red pen is grounded; the black pen is connected with the CPU each Jiko