otis 维修案例(奥的斯维修案例).docVIP

  1. 1、本文档共9页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
otis 维修案例(奥的斯维修案例)

otis 维修案例(奥的斯维修案例) Xizi Otis XIZIOTIS elevator maintenance -- Xizi Otis XIZIOTIS FB-HLAN[BO] motherboard GVF-III motherboard repair call board motherboard GHE-FMT NPH and GVF-2 universal display panel call sclc-v1.1 communication board NPH-2-SCLB V1.0 driver board INV-BDCC3 switching power supply board EL3-AVR01 board DMC-1 board door door DMD-1 relay board RYBD board FB-MPU (BO) FBDMC (B2) gate board circuit board SDC display board FB-HLAN (BO) FB-IGD (BO) inverter drive plate Xizi Otis XIZIOTISNPX door board maintenance, SDC car top communication board maintenance (Xizi Otis XIZIOTIS elevator parts maintenance) ? fault 1 3100 user complaints elevator cant stop operation, call does not work, the floor display is normal, do not open the door. TT check the TCB fault record 0100, 0105, OVF20 CHK DBD SIG fault record, check SW1, 2 relay, SW1 relay assisted bad contact, after the replacement of normal. Fault 2 T60 elevator user complaints in the flat position repeatedly open and close, need to close several times before running, most of the time normal. Check the MIB board and frequency converter without fault recording. Observe in the computer room, wait for the breakdown to appear. Found in the presence of failure U, D relay immediately after the break, check with a multimeter U, D relay A1 voltage, there is no voltage at the time of the fault with fault fault free registration, suspected fault should be in the security checkpoint after checking the car door, hall door contact normal, temporarily not check out the point of failure, and to observe the operation, found in LB after U, the relay D relay will be disconnected, check the drawings, LB relay basically had no effect on U, D relay. Then hold the LB relay by hand and make it artificially controlled, and the fault is not found. Suspected LB relay fault, will control the relay contact the main cabinet check, found that 13-14 SDP 50-200 relay contact resistance in ohms, the contact fault frequency was significantly

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档