功率模块的检修方法(Maintenance method of power module)
功率模块的检修方法(Maintenance method of power module)
In the variable frequency discharge machine
When the confirmation module needs to be changed, please pay attention to check whether the outdoor computer board has been completed discharge, because the fault often has blown machine power circuit, discharge speed is relatively slow. Through the visual indicator plate is completely extinguished, can be directly used by the test voltage between P-N million is lower than that of 36V DC gear. Confirmed after the completion of discharge can remove the module. The main points related to personal safety, but also can avoid the new replacement module installed in high-voltage broken.
The control of AC variable frequency machine downtime phenomenon (general judgment, for reference)
Take the following steps in judgment before, please be sure to let the air conditioning boot operation for a period of time (10 minutes), usually in the opportunity to report the fault code, according to the fault code can help maintenance personnel, the most quickly find the root of the problem, but does not need to consume energy. If the output after a period of time is still no fault code, or still can not determine the specific fault components can be combined with the following phenomenon that the fault location
The frequency conversion machine cabinet is opened, the machine running state in the machine boot
The number outside the machine running state inferred fault causes further confirm the suggestion
1 computer board on any lights are not bright, the fan does not open, not open press may be the main loop outside the machine has a problem, there may be a problem with the object is the bridge rectifier breakdown, fuse, reactor burn, direct detection of a terminal contact terminals arranged on the black and white line voltage is 220V about, if not; and within the machine power and running lights are in machine fault
2 computer board is shown on the red light high light, other lights are not bright,