欧盟压力测试同行审查初步问题PreliminaryQuestions-台电公司回覆
AEC Response to Preliminary Questions TOPIC-1a
Questions and Responses Chapter 2.1.3.3 Chinshan: If there are deviations the station shall follow relevant procedures to carry out safety evaluation and take corrective actions:
a) Do the other sites have the same requirements?
b) How often since the Fukushima-Daiichi accident cases of non-conformance have been reported to AEC?
c) Are non-conformance information processes with information of AEC also in force for other aspects of nuclear safety and were they laid down (e.g. operation manual)?
d) And for which plants?
(a) Yes, all the nuclear power plants follow the same requirements.
(b) There has one non-conformance case, regarding the unprotected ECW system from the specified tsunami run-up height, been reported to AEC by KSNPP, since the Fukushima-Daiichi accident.
(c). Yes, it is carried out in accordance with SOP 1115.01 (The control procedure for the case which does not meet the quality requirement.), all the non-conformance information will be submitted to the AEC in all aspects.
(d). All NPPs are required to follow.
The plant condition for the evaluation of plant robustness regarding external hazards shall be examined on the most unfavourable operation state permitted under plant specification.
The country file doesn’t provide information on shutdown states and doesn’t provide information regarding spent fuel pool safety. Will the analysis be completed?
1. Spent fuel pool is designed to SSE.
2. R/B overhead cranes in CSNPP and LMNPP and fuel building overhead crane in KSNPP are designed as single-failure-proof crane, and normally parked at the place far away from the upper space of the fuel storage pool and the reactor core.
3. Refueling platform is made of seismic class I structure. Under the normal condition, this platform is parked on the lower floor region which is located in between the fuel pool and the reactor core, with the rails of the supporting structure of the said plat
您可能关注的文档
- 数据库技术基础习题.PPT
- 数据库系统原理教程_.DOC
- 数据手册富士通ETERNUSAF650S2全闪存储-Fujitsu.PDF
- 数据挖掘在中国的现状和发展研究-中国科技论文在线.PDF
- 数据挖掘技术在中医诊疗数据分析中的应用-中国中医药信息杂志.PDF
- 数据模型设计操作培训.PDF
- 数据通信与计算机网络第二版电子教案.PPT
- 数据链路控制及其协议-Read.PPT
- 数据热图与内存计算自动化协同优化.PDF
- 整合性海岸管理-海洋事务与资源管理研究所-海洋大学.PDF
- 校园垃圾分类在小学教育中的应用与效果评估教学研究课题报告.docx
- 风向标设计与风力等级判定在高中地理教学中的教学策略研究教学研究课题报告.docx
- 整县分布式光伏等综合能源项目投标书.docx
- 中小学生数字化素养培养背景下的教育资源优化路径探索教学研究课题报告.docx
- 语义网在数字化小学科学教师教学画像构建中的应用与教学实践教学研究课题报告.docx
- 电商包装废弃物回收处理现状与政策支持体系完善教学研究课题报告.docx
- 整县分布式光伏等综合能源项目招商引资报告.docx
- 智慧校园环境下档案信息化的服务优化策略.docx
- 整县分布式光伏等综合能源项目初步设计.docx
- 数据分析在高中英语写作教学中的应用与实践教学研究课题报告.docx
文档评论(0)