- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Measurement of Radiation: Dosimetry Part Three BME College Sherman Sheen(辛学刚) The Physics of Radiology Determination of Absorbed Dose in a Phantom using an Exposure Calibrated Ion Chamber Kerma in the cavity : imagine a small mass, △m, of phantom material placed at point P”,at the center of the air cavity. The (collision) kerma to △m would be: fill in the cavity, of radius c, with phantom material. This would alter the kerma to the small mass, △m, by the attenuation factor, k(cmed), and the kerma to mass △m would now be: the absorbed dose at point P in the homogeneous phantom may be obtained from: to have a dosimeter calibrated in terms of absorbed dose instead of exposure A Farmer type ionization chamber is used to make a determination of absorbed dose in a water phantom irradiated by Co-60 gamma rays. It is protected against the water by thin rubber tubing and is held with its center at a point such as P of Figure 4-12. After a given irradiation the electrometer connected to it gives a scale reading of 74.0. The exposure calibration factor Nx for the chamber with this electrometer is 1.06 for Co-60 radiation. Determine the absorbed dose in the phantom. The outer radius of the chamber with its cap is 0.8 cm. Determine also the dose calibration factor. Determination of Absorbed Dose at Energies Above 3 MeV 1、Use of Exposure Meter with Calibration Factor at Cobalt 60 to Determine Absorbed Dose at Energies above 3 MeV an exposure calibration factor:Nx Determination of Absorbed Dose at Energies Above 3 MeV 2、the cavity-gas calibration factor determined from an absorbed dose calibration. the much simpler equation : Agreed-on Dose Calculation Factors for High Energy Photons Dosimetry for Electron Beams Relation between Energy Fluence and Exposure Summary of Methods to Determine Absorbed Dose This is the Bragg-Gray relation To relates the absorbed dose at a point in a medium to Q, the charge libera
您可能关注的文档
- 《D1_4无穷小无穷大【精品】》-课件设计(公开).ppt
- 《D1_9连续函数运算【精品】》-课件设计(公开).ppt
- 《D8_10最小二乘法【精品】》-课件设计(公开).ppt
- 《D12_5全微分方程【精品】》-课件设计(公开).ppt
- 《DC-HDL-Chapter4-answer》-课件设计(公开).ppt
- 《flash课件第01讲:发展史》-课件设计(公开).ppt
- 《Lektion5EssenundTrinken》-课件设计(公开).ppt
- 《M6S工艺知识》-课件设计(公开).ppt
- 《MATLAB的学习点滴1》-课件设计(公开).ppt
- 《NB使用培训》-课件设计(公开).ppt
- 《Transparancy9》-课件设计(公开).ppt
- 《TS16949_内审员培训材料_》-课件设计(公开).ppt
- 《TS16949培训材料_》-课件设计(公开).ppt
- 《unit4operatorservice》-课件设计(公开).ppt
- 《unit15DealingwithSpecialSituationsinGuestRooms》-课件设计(公开).ppt
- 《vb学习教程9》-课件设计(公开).ppt
- 《VC6++教程实例()第5章》-课件设计(公开).ppt
- 《VC6++教程实例()第9章》-课件设计(公开).ppt
- 《VisulBasic程序设计课件chapter3》-课件设计(公开).ppt
- 《VisulBasic程序设计课件chapter7》-课件设计(公开).ppt
原创力文档


文档评论(0)