网站大量收购独家精品文档,联系QQ:2885784924

《变频器翻译_Michael》.doc

  1. 1、本文档共6页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Memory setting of first frequency after power-off P049 Power down processing Setting range: 0, under voltage fault, then lock-in; 1, under-voltage fault, auto-resetting after power recover, not to start; 2, slow down and stop working when nearly under-voltage. 3, reserved; 4, reserved; The motion setting of converter after power-off and power recover. 0 P050 Reserved P051 Reserved P052 Reserved P053 Option of analog output Setting range: 0, output frequency of analog output, 0-Highest frequency corresponding to 0-10V; 1, output current of analog output, 0-2times of rated current of converter corresponding to 0-10V; This function is used as remote monitoring to output frequency and output power of converter by connecting with a DC Voltmeter or other equipments between AFM and COM terminal. The highest output voltage of AFM terminal is 10V. 0 P054 The corresponding output of the minimum analog quantity Setting range: 0.00-3.00V Setting of signal strength of the terminal under minimum analog quantity (0Hz or 0A). 0.0 P055 The maximum analog quantity Setting range: 5.00-20.00V 10.00 Page 21: Page22: The corresponding output Setting of signal strength of the terminal under maximum analog quantity (highest frequency or 2 times of rated current of converter). Attention: the parameter is used for revising the quantity of analog output, the actual highest output voltage of AFM terminal is 10V. P056 Options of display for starting up Setting range: 0, frequency (H, F); 1, motor current (A); 2, busbar voltage (U); 3, output voltage (u); 4, approximately speed of machine=output frequency﹡ratio of RPM (r); 5, PID fixed variable (y); 6, PID feedback quantity (L); 7, attribute data (J); 8, factory text reserved (d); 0 P057 Ratio of RPM Setting range: 0.01-100.00 The function is used for setting the ratio of display value of speed and working frequency, so as to enable the speed display value to keep consistent with the actual speed. 30.00 P

文档评论(0)

ghfa + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档