Memory setting of first frequency after power-off P049 Power down processing Setting range:
0, under voltage fault, then lock-in;
1, under-voltage fault, auto-resetting after power recover, not to start;
2, slow down and stop working when nearly under-voltage.
3, reserved;
4, reserved;
The motion setting of converter after power-off and power recover.
0 P050 Reserved P051 Reserved P052 Reserved P053 Option of analog output Setting range:
0, output frequency of analog output, 0-Highest frequency corresponding to 0-10V;
1, output current of analog output, 0-2times of rated current of converter corresponding to 0-10V;
This function is used as remote monitoring to output frequency and output power of converter by connecting with a DC Voltmeter or other equipments between AFM and COM terminal. The highest output voltage of AFM terminal is 10V.
0 P054 The corresponding output of the minimum analog quantity Setting range: 0.00-3.00V
Setting of signal strength of the terminal under minimum analog quantity (0Hz or 0A).
0.0 P055 The maximum analog quantity Setting range: 5.00-20.00V 10.00 Page 21:Page22:
The corresponding output Setting of signal strength of the terminal under maximum analog quantity (highest frequency or 2 times of rated current of converter).
Attention: the parameter is used for revising the quantity of analog output, the actual highest output voltage of AFM terminal is 10V.
P056 Options of display for starting up Setting range:
0, frequency (H, F);
1, motor current (A);
2, busbar voltage (U);
3, output voltage (u);
4, approximately speed of machine=output frequency﹡ratio of RPM (r);
5, PID fixed variable (y);
6, PID feedback quantity (L);
7, attribute data (J);
8, factory text reserved (d);
0 P057 Ratio of RPM Setting range: 0.01-100.00
The function is used for setting the ratio of display value of speed and working frequency, so as to enable the speed display value to keep consistent with the actual speed.
30.00 P
您可能关注的文档
最近下载
- 静配中心无菌操作流程.pptx
- 2025年泰州职业技术学院单招职业技能测试题库(历年真题).docx VIP
- PEP版英语三年级下册课件Unit 2《Expressing yourself》Part B(3)Read and write.pptx VIP
- ★安全生产管理方案.doc VIP
- 核磁MRI检查操作规范.docx
- 开阳县新增 200 辆巡游出租车经营权招标文件.PDF
- 工业智能操作系统白皮书(2024版) .pdf
- Unit 2 Expressing yourself Part A 第1课时 课件人教PEP英语三年级下册.pptx VIP
- MotorCAD手册(2022年-2023年新的).pdf
- 牧野J5机床说明书J5_OPERATION_AND_MAINTENANCE_MANUAL(ZH) J7M000G0115C.pdf
文档评论(0)