- 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
D8discaver演讲
General Area Detector Diffraction System(GADDS)-D8DISCOVER a. The fast speed : The speed of data collection with an area detector can be 104 times faster than with a point detector and about 100 times faster than with a linear position-sensitive detector. 2.System configuration of The X-ray Generator Goniometer and X, Y, Z sample Stages Sample Alignment and Monitor Systems * 1. General introduction 2. System configuration 3. Basic System Operation 4. Script Files 5. XRD Evaluation Program 6.Matters needing attention and Problems 7.样品的制备和研究方式、方法 1.General introduction General Area Detector Diffraction System (GADDS), introduced by Bruker AXS, Inc., is the most advanced X-ray diffraction system in the world. The core of GADDS is the high performance two-dimensional(2D) detector Bruker AXS HI-STAR area detector. HI-STAR is the most sensitive area detector, a true photon counter in a large area. Characterization: a. The fast speed b. More information but the result in practice: The speed of data collection with an area detector can be 10~100 times faster than with a point detector(20s : 10min), not considering integration b. More information: The data has large dynamic range and 2D diffraction information. Compared to one-dimensional diffraction profiles measured with a conventional diffraction system, a 2D image collected with GADDS contains far more information for various applications. By introduction of the innovative two-dimensional X-ray diffraction (XRD 2 ) theory, GADDS has opened a new dimension in X-ray powder diffraction. Pinhole Collimator specification(mm): 0.05, 0.1, 0.2, 0.3, 0.5, 1.0 Comparison between single pinhole collimator and double pinhole collimator in terms of intensity gain, beam divergency angle ( ? ), and beam spot size on sample (D). Monocapillary specification(mm): 0.3mm That is, X-rays can be reflected by a smooth surface when the angle of incidence is smaller than the critica
文档评论(0)