Client: Saudi Aramco Plant Location: Saudi Arabia Project Number: P2101 Site Modification Procedure for the gaps of Crane Beam 00 1/3/2012 WBP-0795-SIPS-QP-00059 ISSUED FOR REVIEW AND APPROVAL Wang Yiwen Benjie de Torres Tanveer Ahmed Rev Date Ref. No. Description Prepared By Checked By Approved By PAGE2 / NUMPAGES5 Table of Revisions Section Details of Revision Updates are identified in bold italics Table of Holds Section Details of Hold Hold Cleared (rev) CONTENTS SCOPE REFERENCES INSPECTION AND TESTING ATTACHMENTS Scope This procedure is specailly prepaired for site modification of the gaps between two ajacent crane beams. All the overhead crane beams inside all pump houses , loading racks more or less have the biger gap of more than 1.5mm, which is can,t meet the crane supplier,s requiment . The procedure incorporated the crane suppier’s requirment and IBSF’s suggested solution ,and mainly based on the PROCEDURE FOR STEEL STRUCRE WELDING IN SITE, which is already aproved on ;and WORK PROCEDURE FOR TOUCH-UP FOR COATING aproved on 24.AUG.2011.Meanwhile the procedure Reference AWS D1.1 Structual Welding Code-Steel ASME SEC IX Standard for Welding and Brazing IBSF Shop drawing and Manufacture,s Specification Saudi Crane Manufacture,s Specification Modification procedure Site joint Inspection Shoud be conducted by construction team , Sinopec QC personnal and PID (if required )to measure all the gaps ,and make a record for tracing. The records shall include the Job No, Beam No,gap value, site joint signature For the gap 4mm and above, ask IBSF to provide a slice as filler material, the slice is the same section size of the monorail beam without coating. The thickness of the slice is 1mm smaller than the relevent gap. If the required slice thickness is more than 8mm ,both the slice and the beam should machine 45 degree single bevel inside the flange ,the bevel area is as per the welding area , and the proposed weld be

文档评论(0)

sd44055 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档