XRD--残余应力测试.pptVIP

  1. 1、本文档共45页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Choice of X-Ray Tube (2) Sample Fluorescence If the K-?1 component of the incident X-ray beam causes the sample emit its own fluorescent X-rays, DO NOT USE IT X-ray penetration depth will be very small 5 microns ? NOT representative of the bulk Peak to background ratio will be terrible May damage sensitive detectors Choice of X-Ray Tube (3) Choice of Crystallographic Plane For accurate comparison with other peoples data CHECK which planes have been used historically!! Measurements made on planes with different Miller {hkl} indices are not usually comparable. If the sample is textured (preferred orientation) select a set of planes with a high multiplicity Choice of Measurement Conditions: Summary Ask someone who has experience with that particular material Don’t re-invent the wheel Choose radiation type carefully Avoid X-ray tubes which cause K ?-1 fluorescence Lot’s of “tricks of the trade” see the NPL Good Practice Guide for Residual Stress Measurements using the sin2? Method Data Collection Positioning the Sample Sample must be centre of rotation of the goniometer, most instruments have depth gauge or a pointer Be careful that the sample is as flat as possible, bent samples will give artificial shear stresses For curved and uneven samples restrict the irradiated area Hoop direction, Spot size R/4, where R= radius of curvature Axial direction, Spot size R/2 Data Collection Make sure that you collect data over a sufficient 2? range! Include the background on both sides of the peak. Can be difficult as inelastic is usually present this causes peak broadening. Peaks can be up to 10? 2? Count for a sufficient time to ensure adequate statistics, need 1000 count at the top of the peak if possible Data Processing ALWAYS CHECK THIS STAGE Need a program with good graphics Stages in the data processing Background stripping K-?2 stripping (only if K-?2 peak is visible) Lorentz Polarisation Correction Peak fitting to locate maximum Critical Stage, check the r

文档评论(0)

paoben + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档