RBEs and MPCs in MSC.Nastran.ppt

  1. 1、本文档共94页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
RBEs and MPCs in MSC.Nastran

RBEs and MPCs in MSC.Nastran A Rip-Roarin’ Review of Rigid Elements RBEs and MPCs Not necessarily “rigid” elements Working Definition: Motion at one GRID drives another Simple Translation Motion at one GRID drives another Simple Rotation RBEs and MPCs Small Displacement Theory Rotations Small displacement theory: sin(?) = tan(?) = ? cos(?) = 1 For Rz @ A RzB = RzA= ? TxB = (-?)*LAB TyB = 0 Typical “Rigid” Elements in MSC.Nastran Geometry-based RBAR RBE2 Geometry- User-input based RBE3 User-input based MPC Common Geometry-Based Rigid Elements RBAR Rigid Bar with six DOF at each end The RBAR The RBAR is a rigid link between two GRID points The RBAR Can mix/match dependent DOF between the GRIDs, but this is rare The independent DOFs must be capable of describing the rigid body motion of the element RBAR Example: Fastener Use of RBAR to “weld” two parts of a model together: RBAR Example: Pin-Joint Use of RBAR to form pin-jointed attachment The RBE2 One independent GRID (all 6 DOF) Multiple dependent GRID/DOFs RBE2 Example Rigidly “weld” multiple GRIDs to one other GRID: RBE2 Example Note: No relative motion between GRIDs 1-4 ! No deformation of element(s) between these GRIDs Common RBE2/RBAR Uses RBE2 or RBAR between 2 GRIDs “Weld” 2 different parts together 6DOF connection “Bolt” 2 different parts together 3DOF connection RBE2 “Spider” or “wagon wheel” connections Large mass/base-drive connection RBE3 Elements NOT a “rigid” element IS an interpolation element Does not add stiffness to the structure (if used correctly) RBE3 Description RBE3 Description By default, the reference grid DOF will be the dependent DOF Number of dependent DOF is equal to the number of DOF on the REFC field Dependent DOF cannot be SPC’d, OMITted, SUPORTed or be dependent on other RBE/MPC elements RBE3 Description UM fields can be used to move the dependent DOF away from the reference grid For Example (in 1-D): RBE3 Is Not Rigid! RBE3 vs. RBE2 RBE3 allows warping and 3D effects In this e

文档评论(0)

l215322 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档