乳山锅炉规程修订版
乳山绿色动力再生能源有限公司
锅炉运行规程
乳山绿色动力再生能源有限公司
二0一三年十月
前 言
编制说明:
本规程规定了垃圾焚烧锅炉的运行方式、正常运行时参数的调整和控制、自动控制与保护的动作顺序,事故处理的原则等技术规定。
本规程编制引用资料:
本规程主要依据相关典型运行规程、厂家的技术资料、相关操作调试手册、运行实践经验编制,适用于安徽金鼎锅炉有限公司生产的型号SLC250-22.7-4.0/400单汽包自然循环余热锅炉,根据我厂的设备系统特性汇编成本规程。
应该熟悉、掌握该规程的人员
值长、全能值班员和锅炉专业相关运行人员应熟悉和掌握本规程的全部内容。
锅炉专工、技术员应熟悉和掌握本规程的全部内容。
检修人员、安全监察人员应熟悉和掌握本规程的相关部分。
其他部门应熟悉和掌握本规程的人员由各部门自行规定。
本规程主要编制人员
本规程应在实践中补充修正由于修编水平和时间有限,本规程中不妥、疏误之处在所难免。殷望各位指正,以便及时更正及再版时修订。
本规程自2013年 月 日起开始执行。
目 录
第一篇 锅炉概述
一. 项目概况···················································7
二、主要设备和设计规范·········································8
三. 焚烧炉主要技术指标·········································17
四.主要辅助设备特性···········································18
五. 汽水质量标准··············································20
第二篇 锅炉机组的启动前的检查和准备
一、启动前的检查···············································20
二.锅炉进水···················································24
三.转动机械试运行·············································26
四. 漏风试验···················································26
五. 联锁保护试验···············································27
第三篇 锅炉的启动
一、锅炉冷态启动的准备········································28
二、锅炉启动前的进水··········································28
三、点火的步骤················································29
四、升压操作规定··············································29
五、锅炉并汽条件··············································30
六、锅炉并汽操作··············································30
第四篇 锅炉运行控制和调整
一、锅炉运行调节任务··········································30
二、锅炉运行监视及检查········································31
三、主要参数和燃烧的调节方法··································33
第五篇 锅炉的基本操作
一、水压试验··················································37
二、过热器的反冲··············································38
三、锅炉辅机联锁和事故按纽试验································39
四、转动机械试运··············································40
五、燃烧器的投入和停运········································41
六、水位计水位不明的“叫水”···································41
七、定期排污·