乳山锅炉规程修订版.doc

  1. 1、本文档共101页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
乳山锅炉规程修订版

乳山绿色动力再生能源有限公司 锅炉运行规程 乳山绿色动力再生能源有限公司 二0一三年十月 前 言 编制说明: 本规程规定了垃圾焚烧锅炉的运行方式、正常运行时参数的调整和控制、自动控制与保护的动作顺序,事故处理的原则等技术规定。 本规程编制引用资料: 本规程主要依据相关典型运行规程、厂家的技术资料、相关操作调试手册、运行实践经验编制,适用于安徽金鼎锅炉有限公司生产的型号SLC250-22.7-4.0/400单汽包自然循环余热锅炉,根据我厂的设备系统特性汇编成本规程。 应该熟悉、掌握该规程的人员 值长、全能值班员和锅炉专业相关运行人员应熟悉和掌握本规程的全部内容。 锅炉专工、技术员应熟悉和掌握本规程的全部内容。 检修人员、安全监察人员应熟悉和掌握本规程的相关部分。 其他部门应熟悉和掌握本规程的人员由各部门自行规定。 本规程主要编制人员 本规程应在实践中补充修正 由于修编水平和时间有限,本规程中不妥、疏误之处在所难免。殷望各位指正,以便及时更正及再版时修订。 本规程自2013年 月 日起开始执行。 目 录 第一篇 锅炉概述 一. 项目概况···················································7 二、主要设备和设计规范·········································8 三. 焚烧炉主要技术指标·········································17 四.主要辅助设备特性···········································18 五. 汽水质量标准··············································20 第二篇 锅炉机组的启动前的检查和准备 一、启动前的检查···············································20 二.锅炉进水···················································24 三.转动机械试运行·············································26 四. 漏风试验···················································26 五. 联锁保护试验···············································27 第三篇 锅炉的启动 一、锅炉冷态启动的准备········································28 二、锅炉启动前的进水··········································28 三、点火的步骤················································29 四、升压操作规定··············································29 五、锅炉并汽条件··············································30 六、锅炉并汽操作··············································30 第四篇 锅炉运行控制和调整 一、锅炉运行调节任务··········································30 二、锅炉运行监视及检查········································31 三、主要参数和燃烧的调节方法··································33 第五篇 锅炉的基本操作 一、水压试验··················································37 二、过热器的反冲··············································38 三、锅炉辅机联锁和事故按纽试验································39 四、转动机械试运··············································40 五、燃烧器的投入和停运········································41 六、水位计水位不明的“叫水”···································41 七、定期排污·

文档评论(0)

haihang2017 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档