3120-F321-P7T1-W02D-20A,3120-F321-P7T1-W02D-15A, 规格书,Datasheet 资料
Thermal Overcurrent Circuit Breaker 3120-F...
www.e-t-a.deIssue D 2 - 67
2
Description
Typical applications
Approvals
Technical data
An extremely versatile range of rocker switch/thermal circuit breakers
(S-type TO CBE to EN 60934 with trip free mechanism) offering the choice
of single pole, double pole with single pole protection, and double pole
with protection on both poles. Designed for snap-in panel mounting with
versions available for three different panel cut-out sizes. Illumination is
optional and there is a range of colours and markings for the rocker.
Add on modules:
● Under voltage release coil (for double pole versions only).
● Magnetic trip coil for short circuit protection.
● Magnetic trip coil for remote relay trip.
● Auxiliary contacts for status signalling.
Approved to CBE standard EN 60934 (IEC 60934).
Meets the requirements regarding fire resistance of EN 60335-1 : 2007-02
Safety of household and similar electrical appliances.
Motors, transformers, solenoids, extra low voltage wiring systems, office
machines, electro-medical equipment, power supplies, communications
systems, medical equipment to EN 60601.
3120-F3...F5 3120-F7
For further details please see chapter: Technical Information
Voltage rating AC 240 V; DC 50 V
(AC 415 V to special order)
(UL: AC 250 V; DC 50 V)
Current ratings 0.1...20 A
(up to 30 A to special order, single pole only)
Typical life 1-pole
AC 240 V: 0.1...20 A 30,000 operations at 1 x IN, inductive
DC 50 V: 0.1...4 A 30,000 operations at 1 x IN, inductive
4.5...16 A 30,000 operations at 1 x IN, resistive
DC 28 V: 0.1...20 A 30,000 operations at 1 x IN, inductive
2-pole
AC 415 V: 0.1...16 A 10,000 operations at 1 x IN, inductive
AC 240 V: 0.1...16 A 50,000 operations at 1 x IN, inductive
17...20 A 30,000 operations at 1 x IN, inductive
DC 50 V: 0.1...16 A 50,000 operations at 1 x IN, inductive
17...20 A 10,000 operations at 1 x IN, inductive
Ambient temperature -30..
您可能关注的文档
- 2011年燕山大学翻译硕士MTI考研真题解析及复习方向解析.pdf
- 2011年英语非中心城区一模二模完形填空整理 -- Rush_FTK.docx
- 2011年英语非中心城区一模二模阅读C_D篇整理 -- Rush_FTK.docx
- 2011年青岛大学翻译硕士MTI考研真题答案解析.pdf
- 2011年高等学校招生全国统一考试 英语(安徽卷).doc
- 2011年高等学校招生全国统一考试(安徽卷.doc
- 2011改善皮肤最好用的方法.pdf
- 2012 AutoCAD初级工程师参考样题.pdf
- 2012-2013学年市南区二模试题--香中.doc
- 2012-2013年学年度下学期七年级英语段考试卷.doc
- 2025年国家电网招聘之文学哲学类题库(夺冠系列).docx
- 2025年国家电网招聘之电网计算机题库附答案【名师推荐】.docx
- 2025年国家电网招聘之文学哲学类题库附答案(黄金题型).docx
- 2025年国家电网招聘之文学哲学类题库【夺冠系列】.docx
- 2025年国家电网招聘之电网计算机题库【综合题】.docx
- 2025年国家电网招聘之人力资源类考试题库含答案(名师推荐).docx
- 2025年国家电网招聘之电工类题库附参考答案(考试直接用).docx
- 2025年国家电网招聘之电工类题库附参考答案(培优b卷).docx
- 2025年国家电网招聘之电网计算机题库(基础题).docx
- 现代农业创业计划.pptx
文档评论(0)