RAID5同时坏两块硬盘的处理办法(国外英文资料)
RAID5同时坏两块硬盘的处理办法
RAID5 also deals with two hard disks at the same time
The way to do this is by trying to force online the back of the block, and then rebuild the raid, and then reusing the opportunity to replace the broken one and rebuild it. All of these are Online, but its best to change the bad one and rebuild it again. But not every time, you can force Online success. The data is completely destroyed if the first problem is forced ONLINE, and if the problem is redone. Typically, there is a very low chance that two or more hard drives in a raid 5 will occur at the same time, but that doesnt mean it wont happen. The most common case is a hard drive, which causes the server to crash when there is no discovery, or if it is not replaced in time. This time must be after analysis which piece of plate is wrong, because this piece of the data on the disk is the fresh, combined with the data of other hard disk in the RAID is complete, and can be used normally.
One example of data recovery occurs when two hard disks in raid 5 fail
Cheap Redundant Disk Array RAID (Redundant Array of Inexpensive Disk) is a kind of large capacity, high speed and high reliability of the external memory, is now in a variety of high-performance servers, workstations, and should be widely in large and medium-sized computer
To use. RAID5 level of them no independent check disk parity disk array, using the data block and independent access to technology, can handle multiple access requests in parallel on the same disk that is suitable for access request frequent occasions, such as hospital information system (HIS). Due to the technical features: on a hard disk error, when inserted into the new hard drive, can use the information for the damage to the other hard disk data recovery, but when two pieces of hard disk errors, to restore data will have certain difficulty, has had the similar phenomenon in our hospital in recent.
One, fail to reproduce
Hardware configuration for our hospital: HP LH6000
您可能关注的文档
- 16秋北航《泉币银行学》在线功课三(国外英文资料).doc
- 18.肾阳虚感冒(国外英文资料).doc
- 18.脑血管意外练习题(国外英文资料).doc
- 180儿科护理演习(附谜底)2009营养.演习(国外英文资料).doc
- 17种孕期腹痛大扫描(国外英文资料).doc
- 18平安常识比赛(国外英文资料).doc
- 1956年资料1 邢锡波 赵恩俭 天津市立总病院中医治疗经历介绍(国外英文资料).doc
- 1956年资料11 酒齄鼻的中医疗法(国外英文资料).doc
- 1959年中医资料10 针灸治疗急性阑尾炎疗效及其感化机制的初步商量(国外英文资料).doc
- 1959年资料1 治愈小儿麻痹症病例介绍(国外英文资料).doc
文档评论(0)