安装计算(国外英文资料).docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
安装计算(国外英文资料)

安装计算 When you get the drawing, check the drawing. Symbol awareness: all unmarked figures are in the case of m, except for the highest units, and the other ones are mm. (schedule 1) all the horizontal tubes that come in from the outside are called dry tubes, and from the dry pipe are called the riser, which is called a branch from the riser. Remember to verify that the ratio is correct (1) electrical engineering (including the strong electric part, the weak part and the ground part of the lightning protection) One, strong electrical parts: 1, familiar with drawings: (1) look at the design specifications, the design of engineering materials and instructions of the lightning protection down all that then instructions are coated with legend, all the illustrations need to count the number of distribution box (different sizes, lamps and lanterns, sockets, switches, etc.) are respectively the statistics number; When you look at the system diagram, you should understand the direction of the pipe. The upper and lower directions of the system graph are generally indicated by a point or circle in the plane graph. The left and right sides of the system chart are left and right on the floor plan; The slope of the diagonal line in the system graph is 45 degrees, indicating the pipeline that goes around the plane. The height of the vertical tube on the system diagram, the horizontal segment length of the dry tube and the branch of the branch can be measured. 2, quantity calculation process: first, from the outside - - - the total distribution box - - - unit distribution box - - - indoor distribution box - - - each loop (lighting, socket, etc.). Step 3: calculate the line after the tube (slot), and the pipe (slot) is not in the box, line (cable) into the box. Relevant regulations: when the outdoor wiring drawings are not marked on the outside, it is reserved for 1.5m (outdoor and outer wall). The length of the cable is 2m and the length of the wire into the box is half the perimete

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档