网站大量收购独家精品文档,联系QQ:2885784924

三月一月一考(国外英语资料).doc

  1. 1、本文档共10页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
三月一月一考(国外英语资料)

三月一月一考 Department: maintenance breakout team: Name: Test time: Datun power plant in three rules breakout class test Short answer questions in individual choice case total judgment Score First, individual choice (6 points per game, 30 points) The 1. zirconia oxygen meter shall have an accurate measuring structure, and its operating temperature must be. A.500 B.850 or so, about C.1200 degrees Celsius, the answer B 2.. The Engineer shall receive () agreement before the start of the on-line configuration work. A. B. operation monitor branch director C. long 3, if the spring tube pressure gauge drive mechanism is not clean, will make it (). A. zero high, B. variation big, C. range drop 4, standardized throttling device is (). A. venturi tube, B., eccentric orifice plate, C. wing, dynamic pressure tube 5, the accuracy level of the instrument is expressed by which of the following errors?. A. system error, B. absolute error, C. allowable error Two, judgment questions (6 points per game, 30 points) 1, the thinner the thermocouple wire, the smaller the thermal junction, the smaller the thermal inertia. (V) 2. The absolute value of error is absolute error. () 3. The function of the electric pressure transmitter is to change the pressure signal into electrical signal, so that it is easy to transmit and display. (V) 4. The electric contact water level meter can provide water level signal for the boiler feed water conditioning system. () 5, a physical atmospheric pressure is numerically equal to 1 of the engineering atmospheric pressure. () Three, questions and answers (10 points per game, 20 points) 1, thermal engineering team safety red line? Correctly wear safety protection equipment; DCS configuration work should be handled according to procedures; equipment maintenance should first cut electricity; after the examination of electricity. 2, when checking oxygen pressure gauge, why forbid oil? Because the oxygen pressure gauge station is stained with oil, when in use, the oil

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档