医用光学纤维内窥镜漏水故障分析(Analysis of leakage failure of medical optical fiber endoscope)
医用光学纤维内窥镜漏水故障分析(Analysis of leakage failure of medical optical fiber endoscope)
Analysis of leakage failure of medical optical fiber endoscope
Medical optical fiber endoscope has been in the hospital examination, treatment, operation, widely used in scientific research, the leakage phenomenon is one of the most common fault in medical fiberscope fault, light effect observation, serious when makes the fiber endoscope scrap.
Check whether the machine is leaking, the operator must first understand the structure and function of fiber endoscope (orin buss and engage in Japan series fiber endoscope, for example), fiber endoscope consists of the eyepiece, light joints, and insert the operation.
The eyepiece
Used for observation of images and connection cameras and photographic equipment.
Light guide joint
For guiding light, water, steam supply and connecting cold light source, attractor and ancillary equipment.
Operation department
Used to adjust the direction of the desired image, the position of the treatment and the adjustment of water, gas, and the amount of attraction.
Insert the
Used to insert organs in the body. Its structure is complex, mainly include objective lens, guiding beam, guide beam, apex, bend pipe, snake tube, bend rubber, water pipe and attract pipeline.
The basic structure of optical fiber endoscope as mentioned above, but as a result of their applications were different and produce all kinds of different types of endoscopy, including upper gastrointestinal fiberscope (upper), colonoscopy, enteroscopy, duodenum mirror, bronchoscopy and choledochoscope. In order to facilitate treatment, there are different types and structural parts.
The following introduces the phenomenon of the leakage of optical fiber endoscope and the causes of these phenomena
Image blur
Once the endoscope leaks, the initial image is not clear. But not sure the image blur is caused by leaking, it is possible that apex protection glass is not clean or wear away, or oily mist is objec
您可能关注的文档
- 12种迅速摆平突发状况的技巧(12 quick tips on how to get a quick fix).doc
- 1亿公司转让 PM2.5空气 13811口4567口01(Over 100 million companies transferred PM2.5 air from 13,811 to 4,567).doc
- 1电网络运算放大器逻辑变量触发器二极管(1. Power network operational amplifier logic variable trigger diode).doc
- 2.4G干扰(2.4 G).doc
- 2一周一练a4(2 Monday exercise a4).doc
- 2.全瓷材料的疲劳损伤及咬合病(2. Fatigue damage and occlusion of all porcelain materials).doc
- 3 保证安全的组织措施(3. Ensure the safety of the organization).doc
- 2建90个实务重点(Build 90 practical priorities).doc
- 3-1气候及其在地理环境中的作用(3-1 climate and its role in geographical environment).doc
- 3.35 BOSS传送坐标(3.35 BOSS transmission coordinates).doc
- 数据仓库:Redshift:Redshift与BI工具集成.docx
- 数据仓库:Redshift:数据仓库原理与设计.docx
- 数据仓库:Snowflake:数据仓库成本控制与Snowflake定价策略.docx
- 大数据基础:大数据概述:大数据处理框架MapReduce.docx
- 实时计算:GoogleDataflow服务架构解析.docx
- 分布式存储系统:HDFS与MapReduce集成教程.docx
- 实时计算:Azure Stream Analytics:数据流窗口与聚合操作.docx
- 实时计算:Kafka Streams:Kafka Streams架构与原理.docx
- 实时计算:Kafka Streams:Kafka Streams连接器开发与使用.docx
- 数据仓库:BigQuery:BigQuery数据分区与索引优化.docx
文档评论(0)