30 600MW 2015.№1 600MW 610072 600MW TM312 A [] 1000-3983(2015)01-0030-05 Analysis and Diagnosis of Ground Fault and Inter-turn Short Circuit of Rotor Winding in 600MW Turbo-generator JIANG Jianming, SONG Gongyi, LI Yanhai (China Electric Power Research Institute of Science And Technology, Chengdu 610072, China) Abstract: This paper introduces a kind of rotor winding grounding fault locating method. When the rotor winding of turbo-generator has grounding fault, a large current method can be used for diagnosis and it can find the grounding position roughly. But the large current method need a large capacity power supply and has the risk of damaging rotor. For hydrogen-cooled rotor of turbo-generator, to locate the axial and circumferential earthing position, a method that applied DC voltage on rotor winding poles and measured the ground potential by vent hole can be used instead of large current method. The magnetic pole-to-pole short-circuit of rotor winding was caused by foreign metal bodies in a power plant 600MW turbo-generator, then developed the grounding fault, caused serious damage on retaining rings of generator rotor. When severe short-circuit fault as magnetic pole-to-pole short-circuit occurred , the rotor parts was easy to burn because of the large short circuit current, even caused the grounding faults. When both inter-turn short circuit and grounding fault happened simultaneously the generator should be stopped immediately. Therefore, in order to prevent the accident, the possibility of the rotor one poin

文档评论(0)

xiaofei2001129 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档