因此,模拟机只能用于常规放射治疗的定位.ppt

因此,模拟机只能用于常规放射治疗的定位.ppt

  1. 1、本文档共77页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
因此,模拟机只能用于常规放射治疗的定位

Devices for radiation therapy 放射治疗设备 Devices for radiation therapy Kilovoltage units Cobalt-60 units Linear accelerator 近距离治疗机 模拟定位机 立体定向照射设备 Kilovoltage units Up to about 1950, most of the external beam radiotherapy was carried out with x-rays generated at voltage up to 300kVp. Subsequent development of higher-energy machines and the increasing popularity of the cobalt-60 units in the 1950s and the 1960s resulted in a gradual demise of the conventional kilovoltage machines. Kilovoltage units However, these machines have not completely disappeared. Even in the present era of the megavoltage beams, there is still some use for the lower-energy beams, especially in the treatment of superficial skin lesions. Kilovoltage units X射线的产生原理 Characteristic X-rays Bremsstrahlung (braking radiation) X射线治疗机的基本结构 HVL(half value layer) 定义 使用滤过板,吸收软光子,硬化射线(能量、复合滤过板) Kilovoltage units X射线治疗机的分类 Contact therapy:加速势能20~50KV,治疗距离即靶到皮肤距离10cm或更小,治疗深度1~2mm Superficial therapy:加速势能50~150KV, HVL为1~8mm铝,治疗距离10~30cm,治疗深度一般到5mm Deep therapy (orthovoltage therapy):加速势能150~300KV,治疗距离30~40cm,HVL约为1~3mm铜,治疗深度一般到2cm Cobalt-60 units The cobalt-60 source is produced by irradiating ordinary stable Co-59 with neutrons in a reactor. The Co-60 source , usually in the form of a solid cylinder, discs, or pallets, is contained inside a stainless-steel capsule and sealed by welding. This capsule is placed into another steel capsule which is again sealed by welding. The double-welded seal is necessary to prevent any leakage of the radioactive material. Cobalt-60 teletherapy unit manufactured by Theratronics (now MDS-Nordion), Ottawa, Canada: left – actual photo, right – schematic diagram depicted on a postage stamp issued by Canada Post in 1988 in honour of Dr. Harold E. Johns who invented the cobalt-60 unit in the 1950s. Structure of Cobalt-60 units Co-60治疗机一般由以下部分组成: 一个密封的Co-60放射源 一个源容器及防护机头 具有开关的遮线器装置 具有定向线束的准直器 放射源半影 支持机头的治疗机架,用以调节线束方向 治疗床 计时器及运动控制系统 辐射安全及连锁系统 Cobalt-60 units Co-60 γ 射线的平均能量

您可能关注的文档

文档评论(0)

magui + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8140007116000003

1亿VIP精品文档

相关文档