LW36-40.5(W)T2500-31.5型安装使用说明书_0SR.412.001.2_
LW36-40.5(W)/T2500-31.5 型
户外高压交流六氟化硫断路器
(配 SRCT36A 弹簧机构)
安装使用说明书
中华人民共和国
江苏省如高高压电器有限公司
2010 年 02 月
目 录
1.概述 ···························································································································· ···1
2 . 断路器结构及工作原理 ···································································································1
3 . 弹簧操动机构结构及工作原理·························································································8
4 . 电流互感器 ····················································································································10
5 .包装、运输及储存··········································································································· 11
6 . 安装、调整 ····················································································································11
7 . 安装后的现场测试 ········································································································14
8 .使用与维护 ····················································································································16
9 . 随机技术文件 ················································································································18
10.订货须知 ·····················································································································18
附录:1. 内附电流互感器参数表
2. 电器原理图、接线图及互感器端子排列图
3. 外附 CT 端子排列图
4. 外形图
a.无 CT 外形图
b. 内附CT 外形图
c.外附 CT 外形图
5. 六氟化硫气体特性
6. 安装工具及备品一览表
1 概述
1.1 本说明书适用于 LW36-40.5 型自能式户外高压交流六氟化硫断路器(配 SRCT36A
弹簧机构),它详细描述了断路器的安装使用和维护的有关内容,以及在此过程中需要注
意的安全规范和可能出现的危险。任何操作人员在安装和使用断路器前需仔细阅读本
说明书,在确保熟悉相关内容后方可操作。如果仍有疑问或需要更详细的资料,请与
制造商联系。
1.2 LW36-40.5 型自能式户外高压交流六氟化硫断路器适用于交流 50Hz、40.5kV 的电
力系统中,是电力系统的控制和保护设备。该产品可进行频繁操作,并可作为联络断
路器使