化学反应工程课外题-CRE
Conversion and Reactor Sizing
Additional Homework Problems
For the irreversible gas-phase reaction:
the following correlation was determined from laboratory data (the initial concentration of A is 0.2 g mol/L):
?
The volumetric flow rate is 5 m3/s.
Over what range of conversions are the plug-flow reactor and CSTR volumes identical?
What conversion will be achieved in a CSTR that has a volume of 90 L?
What plug-flow reactor volume is necessary to achieve 70% conversion?
What CSTR reactor volume is required if effluent from the plug-flow reactor in part (c) is fed to a CSTR to raise the conversion to 90%?
If the reaction is carried out in a constant-pressure batch reactor in which pure A is fed to the reactor, what length of time is necessary to achieve 40 % conversion?
Plot the rate of reaction and conversion as a function of PFR volume.
Critique the answers to this problem.
Conversion and Reactor Sizing
Additional Homework Problems
Solution
Over what range of conversions are the plug-flow reactor and CSTR volumes identical?
So that it is easier to visualize the solution, we first plot the inverse of the reaction rate versus conversion. This type of plot is often called a Levenspiel Plot.:
?
Recalling the mole balance equations for a CSTR and a PFR:
Until the conversion (X) reaches 0.5, the reaction rate is independent of conversion and the reactor volumes will be identical.
i.e.
?
What conversion will be achieved in a CSTR that has a volume of 90 L?
For now, we will assume that conversion (X) will be less that 0.5. We start with the CSTR mole balance:
?
Our calculated conversion is extremely small.
?
What plug-flow reactor volume is necessary to achieve 70% conversion?
This problem will be divided into two parts, as seen below:
The PFR volume required in reaching X=0.5 (reaction rate is independent of conversion).
?
The PFR volume required to go from X=0.5 to X=0.7 (reaction rate depends on conversion).
?
Finally, we add V2 to V1 and get
您可能关注的文档
- C 程序设计 第12章多态性与虚函数.ppt
- Dataware双机安装.ppt
- energy star 能源之星.pdf
- HEQAG0015-A1SMT检验标准.pdf
- GTK开发平台4.pdf
- GTK开发平台1.pdf
- HP_V3000完全拆解.doc
- HTT系列传热水泥技术资料.pdf
- IEA2007-可再生能源在全球能源供给-基本面.pdf
- Keil C51 V6.xx教程.pdf
- 2020版 沪科技版 高中生物学 必修2 遗传与进化《第4章 生物的进化》大单元整体教学设计[2020课标].docx
- 情绪价值系列报告:春节消费抢先看-国证国际证券.docx
- 精品解析:北京市东直门中学2023-2024学年高二下学期3月阶段性考试(选考)物理试题(解析版).docx
- 2020版 沪科技版 高中生物学 必修2 遗传与进化《第4章 生物的进化》大单元整体教学设计[2020课标].pdf
- 2020版 沪科技版 高中生物学 选择性必修1 稳态与调节《第1章 人体的内环境和稳态》大单元整体教学设计[2020课标].pdf
- 2020版 沪科技版 高中生物学 选择性必修1 稳态与调节《第1章 人体的内环境和稳态》大单元整体教学设计[2020课标].docx
- 液冷盲插快接头发展研究报告-全球计算联盟.docx
- 精品解析:北京市东直门中学2023-2024学年高二下学期3月阶段性考试(选考)物理试题(原卷版).docx
- 精品解析:北京市东直门中学2024届高三考前练习数学试卷(解析版).docx
- 2020版 沪科技版 高中生物学 选择性必修1 稳态与调节《第2章 人体的神经调节》大单元整体教学设计[2020课标].docx
文档评论(0)