Solaris常见提问.docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Solaris常见提问

网上收集了一些solaris的面试题,算是对solaris学习过程的一个总结 1.网友bininbinin 问:在solaris上换掉一个坏的镜像 答: 问:如何设置,solaris的网卡如何做到loadbalance 答: 问:新添加的网卡,如何在solaris主机上识别出来 答: 问:如何添加网络上面的storage,识别新的网络硬盘? 答: 问:如何在线扩文件系统 答: How to replace a failed SCSI disk mirrored with SolsticeDiskSuite (command line method) WITHOUT taking Solaris down: The following assumptions have been made for this example procedure: A. Server name= B. OS = Solaris 7 or 8 C. DiskSuite versions 4.2 or 4.2.1 D. The ‘bad’ disk is hot-swappable. E. Metadevice numbers and state database replicas are taken from those used on the actual system. F. Actual command line syntax is shown in bold text. 1. Collect output from the following: # metastat # metastat -p # metadb -i 2. To identify the disk to be replaced: Examine the metadb -i output. You should see a W in the flags field associated with slice 7 of the disk experiencing write errors. Another indication is to look at the output from the “format” command.Next to the device name the text string “drive type unknown” will appear indicating that the disk label cannot be read and therefore it is very likely that the disk has failed. For this example, we will assume the failed disk device is c0t0d0. 3. Delete any metadevice state database replicas that are on the bad disk: # metadb -d c0t0d0s7 # metadb -i (to make sure they have been deleted) 4. State of the submirrors: The “metastat” command output reports that all submirrors on the bad disk are at a State of “Needs maintenance”. This indicates that DiskSuite has automatically disabled the submirrors, so there is no need to “metadetach” the submirrors. 5. Physically replace the failed hot-swappable disk. 6. Partition the new disk: Easiest way to do this is to copy the partition table from the root mirror (c0t1d0s2) to the new disk (c0t0d0s2) with the following dd command: # dd if=/dev/rdsk/c0t1d0s2 of=/dev/rdsk/c0t0d0s2 count=16 Verify the partition table was copied correctly using the format utility. Type format, select the correspon

文档评论(0)

cgtk187 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档