- 0
- 0
- 约3.41千字
- 约 8页
- 2020-11-23 发布于广东
- 举报
Correlation between measurement
and 3D EM simulation for 25Gbps
and beyond backplane passive
channel characterization
Lei Yue
Application Engineer
Keysight EEsof EDA
• Evaluation Overview
– Simulate a stripline differential pair located at the 11th layer on
24-layer high speed backplane board up to 50GHz, and correlate
the simulation result of the insertion loss with measurement.
• Objective
– Explore a practical method and tool to quickly and accurately
get the simulation results good matched with measured.
2
Challenges Used slot for non-signal trace planes and
➢ How to ensure the accuracy of PCB characterization and lumped model for ground vias
model extraction up to 50GHz
➢ How to get the accurate results as quickly as possible
➢ Traditional EM solver Momentum and FEM are not fit
for this kind of 24-layer PCB board up to 50GHz
Simulation by 3D planar EM solver aborted
manually at the first frequency point
3
PCB Layout and Stack-up
• Ensure the correct simulation input
Layout Stack-up with Backdrill
3D View
Controlled Line Impedance Analysis
Material Definition