中科曙光虚拟化培训教程汇总:4.1 PSoD(紫屏) of ESXi.pdfVIP

  • 177
  • 0
  • 约5.87千字
  • 约 8页
  • 2021-02-26 发布于安徽
  • 举报

中科曙光虚拟化培训教程汇总:4.1 PSoD(紫屏) of ESXi.pdf

紫屏(PSOD) of ESXi 示例1 : 紫屏输出:MCE The purple diagnostic screen shows a message similar to:  Machine Check Exception: Unable to continue  Hardware (Machine) Error  PCPU: 1 hardware errors seen since boot (1 corrected by hardware) Explanation: The machine check architecture is a mechanism within a CPU to detect and report hardware issues. When a problem is detected, a Machine Check Exception (MCE) is thrown. If an MCE is thrown and a purple diagnostic screen displays, a hardware problem has caused it. There is no other way to generate an MCE. Cause: hardware failure Resolution: Check memory, CPU, Motherboard or else. 示例2 : 紫屏输出: PCPU 1 locked up. Failed to ack TLB invalidate. Explanation :物理 CPU 在尝试清除内存页表时出现故障。 发生中断时,必须执行上下文切换。 在加载新上下文和加载新 TLB 之前, 需要刷新当前 TLB 或使其失效。 当物理 CPU 在较长时间内无法执行此刷 新时,会出现此类型的紫色诊断屏幕(紫屏)。 Resolution :尝试重启。Failed to ack TLB Invalidate 可能由硬件或软件问题引起,如果重启 不行,需要进一步提取日志来判断。 诊断屏 错误 对 错误进 紫色屏幕生成的 VMkernel 错误消息可用于确定问题原因。不过,产生的错误消息数是有 限的。以下是已知的 VMkernel 错误消息列表。  类型:控制台警告 错误示例:COS Error: Oops 描述:ESX 主机出现故障并在出现服务控制台警告时显示紫色屏幕。与大多数紫色 屏幕错误不同的是,该错误并非由 VMkernel 触发。相反,它由服务控制台触发, 并发生在 Linux 级别。这些紫色屏幕错误包含来自 Linux 内核的其他信息。有关 控制台警告的详细信息,请参见Understanding an Oops purple diagnostic screen (1006802) 。  类型:检测信号丢失 错误示例:Lost Heartbeat 描述:ESX VMkernel 和服务控制台 Linux 内核同时在 ESX 上运行。服务控制台 Linux 内核会运行一个称为 vmnixhbd 的进程,只要 VMkernel 能够分配和释放内 存页,该进程便会向 VMkernel 发送检测信号。如果在 30 分钟超时时间之前未收 到检测信号,VMkernel 会触发 COS 严重错误以及表明检测信号丢失的紫色诊断屏 幕。有关检测信号丢失的详细信息,请参见Understanding a Lost Heartbeat purple diagnostic screen (1009525) 。  类型:断言 错误示例:ASSERT bora/vmke