紫屏(PSOD) of ESXi
示例1 :
紫屏输出:MCE
The purple diagnostic screen shows a message similar to:
Machine Check Exception: Unable to continue
Hardware (Machine) Error
PCPU: 1 hardware errors seen since boot (1 corrected by hardware)
Explanation:
The machine check architecture is a mechanism within a CPU to detect and report hardware issues.
When a problem is detected, a Machine Check Exception (MCE) is thrown. If an MCE is thrown and
a purple diagnostic screen displays, a hardware problem has caused it. There is no other way to
generate an MCE.
Cause: hardware failure
Resolution: Check memory, CPU, Motherboard or else.
示例2 :
紫屏输出: PCPU 1 locked up. Failed to ack TLB invalidate.
Explanation :物理 CPU 在尝试清除内存页表时出现故障。
发生中断时,必须执行上下文切换。 在加载新上下文和加载新 TLB 之前,
需要刷新当前 TLB 或使其失效。 当物理 CPU 在较长时间内无法执行此刷
新时,会出现此类型的紫色诊断屏幕(紫屏)。
Resolution :尝试重启。Failed to ack TLB Invalidate 可能由硬件或软件问题引起,如果重启
不行,需要进一步提取日志来判断。
诊断屏 错误 对 错误进
紫色屏幕生成的 VMkernel 错误消息可用于确定问题原因。不过,产生的错误消息数是有
限的。以下是已知的 VMkernel 错误消息列表。
类型:控制台警告
错误示例:COS Error: Oops
描述:ESX 主机出现故障并在出现服务控制台警告时显示紫色屏幕。与大多数紫色
屏幕错误不同的是,该错误并非由 VMkernel 触发。相反,它由服务控制台触发,
并发生在 Linux 级别。这些紫色屏幕错误包含来自 Linux 内核的其他信息。有关
控制台警告的详细信息,请参见Understanding an Oops purple diagnostic screen
(1006802) 。
类型:检测信号丢失
错误示例:Lost Heartbeat
描述:ESX VMkernel 和服务控制台 Linux 内核同时在 ESX 上运行。服务控制台
Linux 内核会运行一个称为 vmnixhbd 的进程,只要 VMkernel 能够分配和释放内
存页,该进程便会向 VMkernel 发送检测信号。如果在 30 分钟超时时间之前未收
到检测信号,VMkernel 会触发 COS 严重错误以及表明检测信号丢失的紫色诊断屏
幕。有关检测信号丢失的详细信息,请参见Understanding a Lost Heartbeat purple
diagnostic screen (1009525) 。
类型:断言
错误示例:ASSERT bora/vmke
您可能关注的文档
- 中科曙光存储培训教程汇总:曙光存储产品线讲解 -2018V1.0.pptx
- 中科曙光存储培训教程汇总:中科曙光DS900高端存储安装和配置.pptx
- 中科曙光存储培训教程汇总:中科曙光DS900高端存储基本结构.pptx
- 中科曙光存储培训教程汇总:中科曙光DS900高端存储命令行介绍.pptx
- 中科曙光存储培训教程汇总:中科曙光DS900高端存储协议配置介绍.pptx
- 中科曙光存储培训教程汇总:中科曙光DS900高端存储总览.pptx
- 中科曙光服务器培训教程汇总:Linux系统初级培训.pptx
- 中科曙光服务器培训教程汇总:Linux系统管理和维护.pptx
- 中科曙光服务器培训教程汇总:操作系统异常情况处理.pptx
- 中科曙光服务器培训教程汇总:服务器基础知识-v0.3.pptx
原创力文档

文档评论(0)