ABB热电偶套管选型设计计算指南Thermowell Calculation Guide V1.3 根据ASME PTC 19.3 TW-2010.ppt

ABB热电偶套管选型设计计算指南Thermowell Calculation Guide V1.3 根据ASME PTC 19.3 TW-2010.ppt

  1. 1、本文档共19页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
* ? ABB Group * | Slide * ? ABB Group * | Slide * ? ABB Group * | Slide * Thermowell Calculation Guide In accordance with ASME PTC 19.3 TW-2010 Andrew Dunbabin March 2012 ? ABB Group * | Slide * Introduction ASME PTC 19.3 TW-2010 was written to replace ASME PTC 19.3-1974 following some catastrophic failures in non-steam service, these thermowells passed the criteria laid out in 1974. The 2010 standard includes significant advances in the knowledge of thermowell behaviour. ASME PTC TW-2010 evaluates thermowell suitability new and improved calculations including: Various thermowell designs including stepped thermowells Thermowell material properties Detailed process information Review of the acceptable limit for frequency ratio Steady-state, dynamic and pressure stress Failure of a thermowell ? ABB Group * | Slide * In 1995 a thermowell failed in the secondary coolant loop of the Monju fast breeder reactor in Japan. The failure closed the plant for 15 years The thermowell was designed to ASME PTC 19.3 1974 The failure was found to be due to the drag resonance induced on the thermowell by the liquid sodium coolant ? ABB Group * | Slide * Stresses on a Thermowell Thermowells protect temperature sensors from direct contact with a process fluid. But once inserted into the process, the thermowell can obstruct flow around it, leading to a drop in pressure. This phenomenon creates low pressure vortices downstream of the thermowell. These vortices occur at one side of the thermowell and then the other, which is known as alternating vortex shedding. This effect can be seen in the example of a flag pole rippling a flag in the wind ? ABB Group * | Slide * Frequency Ratio Vortex shedding causes the thermowell to vibrate. If this vortex shedding rate (fs) matches the natural frequency (fnc?) of the thermowell, resonance occurs, and dynamic bending stress on the thermowell greatly increases The vortex shedding rate for the drag and lift must be calculated.

文档评论(0)

GG-水处理 + 关注
实名认证
内容提供者

资深水处理工程师,环保工程师

1亿VIP精品文档

相关文档