NX-series Temperature Control Unit
NX-TC
Optimize Control by Detecting Status Changes
Easily Satisfy Both Productivity and Quality
• Provide optimal control for wide range of temperature control.
Furthermore, automatically adapts to changes in the operating
environment and measurement object conditions to realize optimum
control. (Adaptive control)
• Functions specialized for packaging machines
(Temperature Sensors for Packaging Machines and Automatic Filter
NX-TC2405 NX-TC3405
Adjustment)
• Function specialized for water-cooled extruders (Watercooling Output
Adjustment)
• Function for suppressing temperature variations that can be predicted
(Disturbance Suppression)
Features
• Build-in 2-or 4-loop (Ch) PID control or ON/OFF control functions not required temperature control programming
• With heater burnout alarm is available
• Multiple inputs for thermocouple and platinum resistance thermometer input models are available
• Detachable front connector with screwless Push-In Plus terminals for easy installation and maintenance
• Monitoring for ambient temperature is available
• Function added to Unit Versions 1.1and later
• A Temperature alarm is possible. (Includes an LBA: Loop Burnout Alarm)
• Parameters are added to I/O data for adjustment of PID constants, etc.
• Manipulated variable branching enables a manipulated variable with a calculated slope value or offset to be output to another channel.
• Function added to Unit Versions 1.2 and later
• Disturbance Suppression (Pre-boost)
• D-AT (Disturbance Autotuning)
• Resistance thermometer Pt1000 can be input
• Function added to Unit Versions 1.3 and later
• The first decimal place in input types 5: K -200 to 1300°C and 0: Pt100 -200 to 850°C can be counted as a significant figure.
Sysmac is a trademark or regist
您可能关注的文档
- Canon佳能黑白数码复合机imageRUNNER系列1730imageRUNNER 1750 1740 1730 用户指南.pdf
- RS Components 电工电料 PLC 附件 NS-NSRCL1 使用说明.pdf
- RS Components 电工电料 PLC 附件 6ES7954-8LE03-0AA0 使用说明.pdf
- Canon佳能黑白数码复合机imageRUNNER ADVANCE系列6265imageRUNNER ADVANCE 6275 6265 6255 用前须知.pdf
- RS Components 电工电料 PLC 附件 DRT2-ID16 使用说明.pdf
- RS Components 电工电料 PLC 附件 CX02 使用说明.pdf
- Canon佳能大幅面打印机GP系列GP-5200大幅面打印机 imagePROGRAF GP-5300 GP-5200 快速指南.pdf
- RS Components 电工电料 人机界面配件 2711-NC21 使用说明.pdf
- RS Components 电工电料 PLC 附件 CQM1-PD026 使用说明.pdf
- RS Components 电工电料 PLC 附件 WB9Z-CU100 使用说明.pdf
原创力文档


文档评论(0)