2×200MW机组 电气运行规程 QFSN-200-2 (试行本) 徐矿集团新疆阿克苏热电有限公司 编制:王萍莉 初审:郝建军 审核:季立群 审定: 批准: 编 制 说 明 一、本规程编写的依据 1、电力工业部颁发的《发电机运行规程》、《电力变压器运行规程》、《发电机厂用电动机运行规程》、《电力电缆运行规程》、《继电保护及安全自动装置运行管理规程》3、电力设计院有限公司MW机组设计说明书及设计图纸 4、电气主辅设备的产品说明书 5、项目的技术协议7、有限公司的有关规章制度 1、电气运行全体人员 2、值长 3、专责工程师 4、工程技术人员 三、下列人员应熟悉本规程的有关内容 1.公司生产副总经理、总工程师、副总工程师 2.生产的部长、部长助理管理部室的部长及其他相关人员事故处理UPS运行规程 1.交流不停电电源(UPS)系述····························································113 2.设备规范············································································113 3.UPS投入运行应做的试验····························································114 4.UPS电源的运行······································································115 5.UPS电源的故障现象和处理 ·························································118 第十篇 柴油发电机运行规程 1.柴油发电机设备规范 ································································120 2.柴油发电机应做的试验 ·····························································121 3.柴油发电机的启停 ··································································123 4.柴油发电机的调整及维护 ···························································124 5.柴油发电机的事故处理 ······························································126 6.柴油发电机的异常现象处理 ·························································127 附录一 2×200MW机组现场管理工作制度 1.0 交接班制度·····································································130 2.0电气设备巡回检查制度··························································132 3.0电气设备定期试验切换制度·····················································136 附录二 典型操作票 1.  #1发变组由冷备用转运行(#2机类似)··········································137 2.  #1发变组由运行转热备用(#2机类似)··········································141 3. #1高备变由运行转冷备用(带#1高厂变运行)···································144 4.  #1高备变由冷备用转运行(带#1高厂变运行)···································145 5. #1高厂变由热备用转运行(#2高厂变类似)·····································148 6. #1高厂变由运行转热备用(#2高厂变类似)·····································149 7.  1-1低厂变由运行转冷备用(1-2低厂变、公用变类似)··························150 8. 1-1低厂变由冷备用转运行(1-2低厂变、公用变类似)······

文档评论(0)

wdhao + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档