《《First neutronics analysis for ITER bio-shield equatorial port plug》.pdf
Fusion Engineering and Design 87 (2012) 1447–1452
Contents lists available at SciVerse ScienceDirect
Fusion Engineering and Design
j o u rn a l h o me p a ge : w w w. elsev /locate/fusengdes
First neutronics analysis for ITER bio-shield equatorial port plug
Tongqiang Dang a,b,∗ , Dongchuan Ying b , Qi Yang a,b , Michael Loughlin c , Andrew Davis d
a School of Nuclear Science and Technology, University of Science and Technology of China, Hefei, Anhui 230027, China
b Institute of Nuclear Energy Safety Technology, Chinese Academy of Sciences, Hefei, Anhui 230031, China
c ITER Organization, Route de Vinon sur Verdon, 13115 Saint Paul Lez Durance, France
d EURATOM/CCFE Fusion Association, Culham Science Centre, Abingdon, Oxon OX14 3DB, UK
a r t i c l e i n f o a b s t r a c t
Article history: ITER equatorial port cell outside the bio-shield plug is a place to allow personnel access after shutdown
Available online 9 April 2012 that accommodates various sensitive equipment and pipes. Gamma dose rate after shutdown of 1 day
in the port cell should be within 10 Sv/h for occupational safety which is one order of magnitude less
Keywords: than that in the port interspace by the shielding of bio-shield plug. To verify the shielding property
ITER of the bio-shield plug, the distributions of gamma dose rates in port cell were studied. Based on the
Bio-shield plug ITER neutronics model Alite4 which is a three-dimensional ITER tokomak neutronics