J. Marine Sci. Appl. (2015) 14: 450-458
DOI: 10.1007/s11804-015-1335-5
Performance of Marine Power Plant Given
Generator, Main and Distribution Switchboard Failures
*
Amit Kumar and Mangey Ram
Department of Mathematics, Graphic Era University, Dehradun 248002, India
Abstract: Power generation is one of the most essential functions regarding electric generator topologies associated with tidal
of any plant for continuous functioning without any interruption. A turbines. Eti et al. (2007) d