- 9
- 0
- 约1.62千字
- 约 5页
- 2016-06-29 发布于贵州
- 举报
HXD1型大功率交电力机车蓄电池接地故障
HXD1型大功率交流电力机车蓄电池接地故障
金学田
(中国南车洛阳机车有限公司 售后服务部 河南 洛阳)
摘要:针对HXD1型大功率交流电力机车在使用运行中经常会出现的蓄电池接地故障,本文着重阐述机车蓄电池接地检测的原理,极性的判断方法以及此类故障的处理思路和办法。
关键词:110V接地检测继电器、蓄电池接地、绝缘强度
Summary:For HXD1 high-power AC electric locomotive in operation would often use a battery ground fault, this paper focuses on the principle of motorcycle battery ground fault detection, polarity determination method, and the processing of such failure ideas and methods.
Keyword:110V ground detection relay, Battery Ground, dielectric strength
图1:蓄电池接地故障检测电路图
图2:110V接地检测继电器检测蓄电池接地故障电路图
通过电路图分析:手动绝缘检测系统是通过转换开关=32-S02的4个连锁控制的,当开关=32-S02打到中