Evacuation Instruction for Schindler 300P-MRL? Only trained and authorized personnel may use these instructions. Manual operation of the elevator can only be carried out in EMERGENCY situations. The safety circuit may NOT be jumped! Open door of controller cabinet and switch off the main switch [2]! Indicator [6] indicates floor where car is standing. If diode LUET [4] is lit, the car is already in the door zone ±12 cm . The passengers can be immediately evacuated. If diode LUET [4] is not lit, reassure passengers and ask them to stand back from the door and to close it, in case the door i