G8032 Ethernet Ring protection characteristics, architectures….ppt

G8032 Ethernet Ring protection characteristics, architectures….ppt

  1. 1、本文档共23页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
G8032 Ethernet Ring protection characteristics, architectures…

Outline Objectives and Principles Basic protection mechanism Revision notes Detailed functionality Future work Summary Outline Objectives and Principles Basic protection mechanism Revision notes Detailed functionality Future work Summary Objectives and Principles Protection switching on Ethernet layer Use of Ethernet OAM frames called R-APS message for protection behavior Preventing any loops by blocking mechanism VLAN based protection switching Sub-50msec protection switching Support of administrative commands Outline Objectives and Principles Basic protection mechanism Revision notes Detailed functionality Future work Summary Basic protection mechanism Normal condition Block RPL (Ring Protection Link) Failure condition Block failed link Send R-APS messages Unblock RPL Perform FDB flush on all ring node as needed Outline Objectives and Principles Basic protection mechanism Revision notes Detailed functionality Future work Summary G.8032 (06/2008) Revision approved in June 2008 Supported Features Single ring protection Revertive behavior State based flush logic G.8032 (04/2009) Amendment approved in April 2009 Supported Features Multi-ring protection with R-APS Virtual Channel Revertive behavior State based flush logic Flush propagation G.8032 (03/2010) Revision approved in March 2010 Supported Features Multi-ring protection with/without R-APS Virtual Channel Revertive/non-revertive behavior Flush logic with Node-ID and BPR (Blocked Port Reference) mechanism Administrative commands (Manual/Forced switch, Clear) Ability to block RPL at both ends of link Multiple (logical) ERP Instances over a given physical ring Outline Objectives and Principles Basic protection mechanism Revision notes Detailed functionality Future work Summary Interconnected Rings G.8032 supports for a network of interconnected rings based on the following terminology. Interconnection Node connects between Ethernet rings Major Ring constitutes a closed ring is controlled by its own ERP instance

文档评论(0)

sh4125733 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档