SS03-Class10_X-RayCT.pptVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
SS03-Class10_X-RayCT

2/20/2002 SUNY / Polytech - Biomedical Imaging I SS02 Biomedical Imaging I Class 10 – X-Ray Computed Tomography 4/16/03 X-ray computed tomography Limits of radiography / fluoroscopy 3D structures are collapsed into 2D image (obscuring of details, loss of one dimension) Low soft-tissue contrast Not quantitative Features of x-ray CT X-ray imaging modality (same principles of generation, interaction, detection) Generation of a sliced view of body interior Computed reconstruction of images Examples of CT images Principle of x-ray CT In one plane, obtain set of line integrals for multiple view angles Reconstruct cross-sectional views Scanner Design Realization of x-ray CT Mathematical basis for computed tomography by Radon (1917) Idea popularized by Allan Cormack at Tufts Univ. (1963) First practical x-ray CT scanner introduced by Godfrey Hounsfield of EMI Ltd., England (1972) First generation EMI Mark I (Hounsfield), “pencil beam” or parallel-beam scanner (highly collimated source) ? excellent scatter rejection, now outdated 180? - 240? rotation angle in steps of ~1 ? Used for the head 5-min scan time, 20-min reconstruction Original resolution: 80 ? 80 pixels (ea. 3 ? 3 mm2), 13-mm slice Second generation Hybrid system: Fan beam, linear detector array (~30 detectors) Translation and rotation Reduced number of view angles ? scan time ~30 s Slightly more complicated reconstruction algorithms because of fan-beam projection Third generation Wide fan beam covers entire object 500-700 detectors (ionization chamber or scintillation detector) No translation required ? scan time ~seconds (reduced dose, fewer motion artifacts) Reconstruction time ~seconds Pulsed source (reduces heat load radiation dose) Fourth generation Stationary detector ring (600 – 4800 scintillation detectors) Rotating x-ray tube (inside or outside detector ring) Scan time, reconstruction time ~seconds Source either inside detector ring or outside (rocking, nutating detectors) Comparison of 3rd and 4

文档评论(0)

sd44055 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档