污水参考硫化物测定仪(英文版)
Apparatus for measuring sulphides
LC-100S
?
Instructions for use
?
?
?
?
泰州市奥普特分析仪器有限公司
TaiZhou City AoPuTe Analysis Instruments Co. Ltd.
?
?
?
?
?
Chapter I overview
LC-100S?Instrument is based on the principle of microcoulometric titration determination of sulfide, measuring and electrolyte with micro-computer control and data processing system of the new generation of intelligent products.營n the practical application of mea suring results of analysis of high speed, high precision, direct燣CD燿isplay, can print records, solidifying displaying, printing, is highly efficient, fully automatic precision analytical instruments.燱ater quality is the most effective instrument for det ermination of sulfide in testing.燚etermination of sulfur compounds widely used in water quality.
?
Chapter II technical parameter
Measurement methods: micro-coulometry
Measuring range:10PPm-?percent
Resolution:0.01㎎
Detection limit:0.3㎎
Accuracy: ±10%,?when bromine index 10PPm , ±3PPm
Electrolysis control: automatic electrolytic current control
End point detection: double platinum electrodes indicates
Printed:40爉icro printeru
Results display:LCD(liquid crystal) display
Titration of pool volume:200ml
Stirring: magnetic mixers
Power supply:220V?0Hzx
Power:30W
Weight:?.6爇g:2
?
Chapter III works
Sulfide detector analyses principles of water quality are as follows:
When samples containing unsaturated hydrocarbon injection營?s ?In the electrolyte, and samples of unsaturated hydrocarbons in and燘r?te?Following reactions:
S2-+I3-?→S↓+3I-
Depletes?I2, supplemented by electrolytic anode.
2I-?-2e?→I2
Measurement?I2?of the electricity consumed, according to Faradays law to get samples of sulfide content.
Sulfide detector works as follows:
Microcomputer automatic control instruments used electrolysis current, analysis process, the amplifier with titration pool iodine concentration automatic control system.燱hen the pool of sample injection titration, samples of sulfides react with iodine in the electroly
您可能关注的文档
最近下载
- 国标阀门型号编制方法JBT308-2004.PDF
- 2024年福建省能源石化集团有限责任公司春季校园招聘455人笔试参考题库附带答案详解.pdf
- 76G-3预应力长向圆孔板.pdf
- 数字媒体艺术_梦境主题“梦幻之旅”插画绘本设计.docx VIP
- 演示文稿国际结算的几种方式.ppt VIP
- C被遗弃的少女 das verlassene magdlein声乐正谱五线谱钢琴伴奏.pdf
- 七年级下数学数形结合附答案解析.pdf
- 教科版科学四年级下册 第三单元 岩石与土壤 5 岩石、沙和黏土.ppt VIP
- 软件系统试运行报告.doc VIP
- DLT 284_输电线路杆塔及电力金具用热浸镀锌螺栓与螺母.pdf
文档评论(0)