_Comparative MRI Compatibility of 316L Stainless Steel Alloy… 英文书.pdf

_Comparative MRI Compatibility of 316L Stainless Steel Alloy… 英文书.pdf

  1. 1、本文档共8页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
MARCEL DEKKER, INC. ? 270 MADISON AVENUE ? NEW YORK, NY 10016 ?2002 Marcel Dekker, Inc. All rights reserved. This material may not be used or reproduced in any form without the express written permission of Marcel Dekker, Inc. JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCEw Vol. 4, No. 4, pp. 423–430, 2002 ORIGINAL ARTICLE Technical Comparative MRI Compatibility of 316L Stainless Steel Alloy and Nickel – Titanium Alloy Stents Andrea Holton,* Edward Walsh, Andreas Anayiotos, Gerald Pohost, and Ramakrishna Venugopalan Department of Biomedical Engineering, University of Alabama at Birmingham, 1075 13th Street South, Hoehn 370, Birmingham, AL 35294-4440 ABSTRACT The initial success of coronary stenting is leading to a proliferation in peripheral stenting. A signi?cant portion of the stents used in a clinical setting are made of 316 low carbon stainless steel (SS). Other alloys that have been used for stent manufacture include tantalum, MP35N, and nickel – titanium (NiTi). The ferromagnetic properties of SS cause the production of artifacts in magnetic resonance imaging (MRI). The NiTi alloys, in addition to being known for their shape memory or superelastic properties, have been shown to exhibit reduced interference in MRI. Thus, the objective of this study was to determine the comparative MRI compatibility of SS and NiTi stents. Both gradient echo and spinecho images were obtained at 1.5 and 4.1 T ?eld strengths. The imaging of stents of identical geometry but differing compositions permitted the quanti?cation of artifacts produced due to device composition by normalizing the radio frequency shielding effects. These images were analyzed for magnitude and spatial extent of signal loss within the lumen and outside the stent. B1 mapping was used to quantify the attenuation throughout the image. The SS stent caused signi?cant signal loss and did not allow for visibility of the lumen. However, the NiTi stent caused only minor artifacting and even allowed for visualization of

文档评论(0)

新起点 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档