[精品]TLUPI-gb
TL UPI Connections
07. Feb. 2000 98441113147 Datasheet Universal Pulse Interface Seite 1
www.sig-positec.de made by
General Description
The TL UPI (Universal Pulse Interface) is an interface adapter for the pulse/direction interface or Pulse-C
module of a Twin Line Unit and a master control unit (e.g. PLC). It should be mounted as close as possible to
the Twin Line Unit by a simple snap-on connection to a DIN rail. The connection between Twin Line Unit and
TL UPI can be effected by means of a standard Pulse-C cable.
The TL UPI offers several alternatives for wiring signal connections.
The 24 V supply to the TL UPI is made via Phoenix terminals.
Safety Notes
ACHTUNG
ATTENTION
The interface cables with Sub-D connector must be screened. Good electrical connection must
be made between the screen and the connector housing.
Cable screens must be connected at both ends.
The I/O cable screen can be connected by means of Phoenix terminals.
ACHTUNG
ATTENTION
For reasons of interference protection, the length of the Pulse-C cable is limited to max. 3 m.
ACHTUNG
ATTENTION
Connect protective ground contact to protective ground with a short cable (e.g. to PE terminal
for DIN EN rails).
.
TL UPI Connections
07. Feb. 2000 98441113147 Datasheet Universal Pulse Interface Seite 2
www.sig-positec.de made by
Technical Data
Overview
- 12 FUNCT_OUT (O)
- 11 ACTIVE (O)
- 10 STEP2_INV (I)
- 9 STEP2_INV (I)
- 8 PWM (I)
- 7 PWM (I)
- 6 ENABLE (I)
- 5 ENABLE (I)
- 4 +24 V, power supply
- 3 GND
- 2 GND
- 1
*Pulse-C cabel
Order No. 625 014 47 XXX / XXX=005(0,5m); 015(1,5m); 030(3m)
All inputs can be set for 5V push-pull inputs or 24V signals.
The signal level can be selected on P1 by connecting the resistance network.
Only 24V signals may be connected to P3 (e.g. from the I/O card of a PLC).
PULSE / PULSE and DIR / DIR are only connected via P1.
ENABLE / ENABLE , PWM / PWM , STEP2_INV / STEP2_INV can either be connected to P1 or to P3.
This results in the follow