N9322C Datasheet
Agilent
N9322C Basic Spectrum Analyzer
Data Sheet
Easy on your budget.
Tough to beat performance, efficiency and
simplicity.
2Specification
Describes the performance of parameters covered by the product warranty and
apply to the full temperature range of 5 to 45 °C, unless otherwise noted.
Typical
Describes additional product performance information that is not covered by the
product warranty. It is performance beyond specifications that 80 percent of
the units exhibit with a 95 percent confidence level over the temperature range
20 to 30 °C. Typical performance does not include measurement uncertainty.
Nominal
Indicates expected performance, or describe product performance that is useful
in the application of the product, but are not covered by the product warranty.
The analyzer will meet its specifications when:
? It is within its calibration cycle
? It has been turned on at least 30 minutes
? It has been stored at an ambient temperature within the allowed operating
range for at least two hours before being turned on; if it had previously been
stored at a temperature range inside the allowed storage range, but outside
the allowed operating range
Learn more about the
product
Reference these frequently-
used documents:
? Brochure (5991-1166EN)
? Introduces the product
features
? Configuration Guide
(5991-1168EN)
? Describes ordering
information
For the latest revision of prod-
uct related documents or more
information, visit the website:
/find/
n9322c
Definitions and Conditions
3Supplemental information
Frequency
Range 9 kHz to 7 GHz AC coupled
Resolution 1 Hz
Frequency reference
Option PFR Standard
Nominal frequency 10 MHz 10 MHz
Aging rate ± 1 × 10-7 /Year ± 1 × 10-6 /Year
Temperature stability
20 to 30 °C ± 1.5 × 10-8
5 to 45 °C ± 5 × 10-8 ± 1 × 10-6
Achievable initial calibration accuracy ± 4 × 10-8 ± 1 × 10-6
Frequency readout accuracy (start, stop, center, marker)
Marker resolution (frequency span)/(number of sweep point ? 1
您可能关注的文档
- M3_June_2009.doc
- M3U5Warming up.ppt
- M8 U1 zheng.ppt
- Macromolecular Crowding Directs Extracellular Matrix Organization and Mesenchymal Stem Cell Behavior.pdf
- Macroscopic quantum information channel via the polarization-sensitive interaction between.pdf
- Macrozoobenthos in Yangtze floodplain lakes patterns of density, biomass, production to connectivity.pdf
- Magellanic Cloud X-ray Sources III. Completion of a ROSAT Survey.pdf
- magic finger (前).pdf
- Magnetic field dependence of kinetic inductance in Bi2Sr2Ca2Cu3O10 superconducting strip an.pdf
- MagnesiumSilicate.pdf
文档评论(0)