Energy-Calibration of the ATLAS Hadronic and Electromagnetic Liquid-Argon Endcap Calorimete.pdf
- 1、本文档共5页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Energy-Calibration of the ATLAS Hadronic and Electromagnetic Liquid-Argon Endcap Calorimete
a
r
X
i
v
:
p
h
y
s
i
c
s
/
0
3
1
0
1
2
7
v
1
[
p
h
y
s
i
c
s
.i
n
s
-
d
e
t
]
2
4
O
c
t
2
0
0
3
February 2, 2008 3:34 WSPC/Trim Size: 9in x 6in for Proceedings menke
ENERGY-CALIBRATION OF THE ATLAS HADRONIC AND
ELECTROMAGNETIC LIQUID-ARGON ENDCAP
CALORIMETERS
SVEN MENKE?
Max-Planck-Institut fu?r Physik
(Werner-Heisenberg-Institut)
Fo?hringer Ring 6, 80805 Mu?nchen, Germany
E-mail: menke@mppmu.mpg.de
In 2002 the first combined beam test of the hadronic and electromagnetic liquid-
argon endcap calorimeters of the ATLAS experiment took place at the SPS test
beam at CERN. A total of 15 million events from electrons, muons and pions in
the energy range from 6 to 200GeV were recorded. The entire calibration chain,
from digital filter weights, over calibration constants, to clustering and energy
weights, as is relevant for the energy calibration of hadronic and electromagnetic
showers in ATLAS was tested and applied to the beam test data. The calibration
methods and first results for the combined performance of the two calorimeters are
presented.
1. Introduction
1.1. The ATLAS Hadronic and Electromagnetic Endcap
Calorimeters
The ATLAS hadronic (HEC) and electromagnetic (EMEC) liquid-argon
endcap calorimeters 1?3 have to provide accurate measurements of jet en-
ergies and directions, missing transverse energy and particle identification
in the pseudo-rapidity range 1.5 ≤ |η| ≤ 3.2. Methods relevant for the
energy calibration in ATLAS and first results of the combined performance
are subject of this presentation.
1.2. The 2002 Beam Test Setup
1/8 wheel of the EMEC was placed in front of 3 out of 32 HEC1 modules and
2 out of 32 HEC2 half-modules in a cryostat in the H6 test beam area at the
?on behalf of the ATLAS Liquid Argon Collaboration
1
February 2, 2008 3:34 WSPC/Trim Size: 9in x 6in for Proceedings menke
2
CERN SPS. The restriction to 2 half modules of the second HEC wheel was
mainly due to space constraints given by the cryostat. The 2 HEC2 half-
modules were
您可能关注的文档
- Digital Booklet - Happy Accidents_ A Memoir.pdf
- Digital Heaven.pdf
- digital radio frequency memory.pdf
- Digital Signal Processing for High Spectral Efficiency Optical Transmission.pdf
- Dioscurica and the Roots of the Cyclic Tradition TABLE OF CONTENTS Introduction The Prehist.pdf
- Direct adaptive neural control of chaos in the permanent magnet synchronous motor.pdf
- Direct Photons in Nuclear Collisions at FAIR Energies.pdf
- Direct-current nanogenerator driven by ultrasonic waves.pdf
- Disability Services Act 1991.pdf
- Discourse generation using utility-trained coherence models.pdf
文档评论(0)