High strength bolts, VDI2230 - keys
1 / 8 23. Oktober 2008
KISSsoft Tutorial:
Bolt selection and rating according to VDI guideline 2230
__________________________________________________________________________________________
For release 10/2008
kisssoft-tut-004-E-bolts.doc
Last modification 23.10.2008 16:48:00
__________________________________________________________________________________________
1 Starting KISSsoft
1.1 Starting the software
Start KISSsoft using ?Start/Program Files/KISSsoft 10-2008/KISSsoft?. The following window
will appear:
Figure 1.1-1: Start KISSsoft, KISSsoft main window.
1.2 Select Calculation
Using the Module tree window Tab ?Modules?, select the bolt analysis:
Figure 1.2-1: Selecting Calculation Module ?Bolts?.
KI
SS
so
ft
Tu
to
ria
l 0
04
: B
ol
t s
el
ec
tio
n a
nd
ra
tin
g a
cc
or
di
ng
to
VD
I g
ui
de
lin
e 2
23
0
2 / 8
2 Calculation of a flanged connection
2.1 Task description
Sizing and rating of the bolting for a flanged coupling with data as shown:
Torque to be transmitted 13kNm
Pitch diameter 258mm
Number of bolts on pitch circle 12
Material flange (left/right) GG25/34CrNiMo6
Thickness flange(left/right) 22mm/18mm
Surface flange (left/right) N7/N8
Coefficient of friction 0.15
Minimal axial force 0kN
Maximum axial force 10kN
Strength class of bolt 10.9
Hexagon head screw with shank (AB)
ISO4014
Tightening: with dynamometric key
The connection realised with through bolts (notation according VDI 2230:2003 bolted joint)
with nuts and washer under nuts and under bolt head.
This basic data is entered as follows:
Figure 2.1-1: Input of known data, selection of calculation method.
2.2 Proposal for a sensible bolt diameter
After having defined the loads acting and the type/strength of the bolt, the sizing button can be
used in order to have the software proposing a suitable bolt diameter. This proposal is based on a
simplified method as described in VDI guideline 2230, table 7.