配电网低电压解决方案与高效降损配电变压器全无功就地自动补偿的选择

配电网低电压解决方案与高效降损 10/0.4kV配电变压器全无功就地自动补偿的选择 唐寅生1,潘辉2,秦岭3 (1.湖南电力调度通信局,湖南省 长沙市 410007;2、河南电力试验研究院,河南省 郑州450052 ;3.郑州市天一节能技术有限公司,河南省 郑州市 450006) Low-voltage distribution network loss reduction and efficient solutions 10/0.4kV power distribution transformer no automatic compensation for the choice of place TANG Yinsheng 1,PAN Hui2, QIN ling 3, (1. Hunan Electric Power Dispatch Communication Bureau, Changsha 410007, Hunan Province, China;2. Henan Electric Power Research Institute, Zhengzhou 450052;3. Zhengzhou Tianyi Energy Technology Co., Ltd., Zhengzhou City,450052) 摘要:配电网低电压解决方案与高效降损工作的要点是减少通过10kV线路及10/0.4kV配电变压器中电流 的无功分量,即什么地方用无功就在什么地方补偿;什么时候用无功就什么时候补偿;用多少无功就补偿 多少。最好方案是10/0.4kV配电变压器全无功就地自动补偿的选择,同时做好了全网AVC的第一层无功补偿,它也是配网自动化的重要内容之一。因此呼吁在10kV线路杆塔上的无功补偿方法尽快刹车,因为它仅以提高10kV线路出口界面的功率因数为目标,无功补偿效率低,大量浪费了投资,而且降损与电压质量效益都很差;重点介绍并推荐“全无功随器自动补偿装置”及其高效降损性能与特征。 关键词:配电网;高效降损;全无功;随器就地补偿;实用性 Abstract: Low-voltage distribution network loss reduction solutions and efficient work of the main points is to reduce lines and 10/0.4kV through 10kV distribution transformers in the current reactive component, that is where the use of reactive compensation in where; when using reactive when the compensation; how much reactive power compensation on the number. The best solution is 10/0.4kV local power distribution transformers no automatic compensation of choice, while doing the first level of the whole network AVC reactive power compensation. 10kV line tower so called reactive power compensation on the brakes as soon as possible, because it exports only increased 10kV line interface for the target power factor, reactive power compensation inefficient, wasting a lot of investment and loss reduction and voltage quality and efficiency are poor; highlight and recommend no power with the automatic compensation device and its high performance and lower loss characteristics. ,朗读 显示对应的拉丁字符的拼音 Key words: Distribution system; efficient loss reduction; no power; with the local compensation device;Practical;朗读

文档评论(0)

haihang2017 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档