- 1、本文档共14页,可阅读全部内容。
- 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
- 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
PDMS chip enzyme reactor Glucose free
PAGE \* MERGEFORMAT 14
PDMS chip enzyme reactor Glucose free
Of: Zhong Haiyan Zhou Jie Yu Xiaodong CHEN Hong-Yuan
[Abstract] Micro gel electrophoresis analysis of intermediary (EMMA technology, build a polydimethylsiloxane (PDMS chip enzyme reactor free, online detection of glucose (Glu, in the cross-channel chip, using home-made carbon fiber microelectrodes Glucose oxidase (GOD catalyzed oxidation of Glu-generated H2O2, and detection potential, GOD concentration, GOD injection time, separation voltage and other parameters were optimized to determine the free enzyme reactor linear range and detection limit was investigated The reproducibility and stability. The results show that the production of free enzyme reactor convenient, simple, reproducible, Glu concentration in the 0.1 ~ 20 mmol / L a good linear relationship between (r = 0.997, The detection limit was 19.8 μmol / L (S / N = 3.
[Keywords:] free enzyme reactor, glucose, electrophoretic analysis of intermediate micro, polydimethylsiloxane chip
The Key Lab of Analytical Chemistry for Life Science, Ministry of Education, School of Chemistry and Chemical Engineering, Nanjing University, Nanjing 210093) Abstract Microfluidic enzyme based reactor could be used to detect the biomolecules with high sensitivity and selectivity. Based on the electrophoretic mediated microanalysis (EMMA) method, a new kind of free enzyme based poly (dimethylsiloxane) (PDMS) microchip was developed to detect glucose (Glu). On line catalysis reaction of Glu by glucose oxidase (GOD) was carried out on the chip. The product H2O2 was detected using single carbon fibre cylindrical electrode. Factors influencing the separation and detection, such as detection potential, GOD concentration, GOD injection time and separation voltage, were investigated and optimized. Results showed that the peak current had a good linear relationship with Glu concentration in the range of 0.1-20 mmol / L (R = 0.997). The detection limit of Glu w
您可能关注的文档
- Patients on the clinical diagnosis of consciousness.doc
- Patient-controlled epidural analgesia for prostate surgery bladder spasm clinical application of.doc
- Patients over 80 years the clinical application of therapeutic ERCP and prevention of complications.doc
- Patients recovering from anesthesia Analysis and Treatment of restless.doc
- Patients recovering from anesthesia Analysis and Treatment of restless_0.doc
- Patients serving the needs of nurses caring Survey.doc
- Patients undergoing abdominal surgery causes urine retention after pulling catheter Analysis and Prevention.doc
- Patients with active pulmonary tuberculosis smear HRCT score and bacteriological and immunological correlation.doc
- Patients undergoing cancer care during chemotherapy.doc
- Patients with acute cerebral hemorrhage nursing.doc
文档评论(0)