Quality control of blood cell test.doc

  1. 1、本文档共8页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
Quality control of blood cell test

 PAGE \* MERGEFORMAT 8 Quality control of blood cell test Accuracy of test results of blood cells of disease diagnosis, treatment and monitoring have a direct impact. Therefore, we must guarantee the quality, do a good job of blood cell analysis before, during and after the quality control. An analysis of quality control Blood Cell Analyzer 1.1 installation requirements to ensure the normal operation of equipment, the installation should pay attention to: 1.1.1 equipment placed in the electromagnetic interference from sources of heat source location; 1.1.2 Place the test-bed to a solid instrument, apparatus, both sides, rear and above the air space of at least 0.5m, in order to ease maintenance and use, between the rear panel and the wall, leave at least 0.2m, in order to ease heat and cleaning work environment must be clean; 1.1.3 moisture, direct sunlight, good ventilation, indoor temperature should be maintained at 15 ~ 30 , the optimum temperature is 25 , relative humidity of 30% to 85%; 1.1.4 For the safety and anti-jamming equipment, apparatus, application of best cleaning power regulator, and a dedicated ground connection standard. Every time after installation or maintenance of equipment, the technical performance of the instrument must be tested, calibration and evaluation. ICSH released a report on the evaluation of blood cell analyzer program, in the determination of cell count and hemoglobin, the test sample to the instrument’s total variability, carryover, linearity, comparability, repeatability, accuracy of evaluation. The total white blood cell count coefficient of variation should be “3% carryover lt;2%, repeatability” 3%, wide linear range, the electrical impedance method should be leukocyte cell classification clustering should pay attention to compliance with the microscopic examination; 1.1.5 calibration of instruments, apparatus or equipment inspection, after repair or replacement parts six months after clin

您可能关注的文档

文档评论(0)

hhuiws1482 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:5024214302000003

1亿VIP精品文档

相关文档