Lab3ReflectionCoefficientandMatching.docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Lab3ReflectionCoefficientandMatching

Lab 3: Smith Chart and Single-Stub Tuning NAME_______________NAME_______________NAME_______________ Introduction: In this experiment you will measure the impedance as well as the reflection coefficient of a 24-ohm low frequency load resistor at different microwave frequencies using a network analyzer HP 8753A, and also match the load impedance to 50 ohms at a single frequency 500 MHz using single-stub tuning techniques. The system, an HP 8753A network analyzer measures the complex one port reflection coefficient or simply . Calibration of the instrument is done with a standard open load, a standard short load and a standard 50-ohm load (all from the calibration kit). Calibration is required before the measurement if the settings are changed on the instrument. This system uses real time analog signal processing exclusively. Measurements can be done over wide frequency sweeps (linear frequency sweep from 0.3 MHz - 3 GHz) to see overall trends and then individual frequency points (CW frequency) examined for details. By plotting the component input impedance on a Smith Chart we can rapidly match the component to 50 ohms. This involves selecting the correct lengths of transmission lines to act as impedance transforming elements, as described in section 2-10 of the text. Network Analyzer Calibration Procedure: Turn on the instrument. Press “preset” on the front panel “format” on the front panel ( “Smith chart” softkey “cal” on the front panel ( “calibrate menu” softkey ( “S11 1-port” softkey Connect the standard open load from the cal kit and press the softkey “open”. After the “open” calibration, change the load to the standard short load from the cal kit and press the softkey “short”. After the “short” calibration, change the load to the standard 50-ohm load from the cal kit and press softkey “load”. After the calibration process, press “done 1-port cal” at the bottom and then “save reg. 1”. Now the calibration data are saved in register 1 on the i

文档评论(0)

***** + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档