功课典范(国外英文资料)
作业范例(国外英文资料)
The joint welds of the shear plate and the surface of the column flange are double-sided fillet welds, and the size of the welding feet is 8mm. The weld calculation is shown in table 1.
Table 1 weld strength check table
Weld form
The shear strength
Design value FVW (MPa)
A single weld
Calculate length (mm)
Weld leg size
(mm)
Shear capacity
(kN)
Fillet weld
160
200
8
179 kn
The length of the bending length of the concrete foil bar is not less than 15d, the length of the column is not less than 100mm, and the protective layer is 20mm. Reinforced ribs end up 135 ° hook, protective layer thickness of 30 mm.
Five. Finite element calculation results
Due to the special structure form of the combination of flat slab floor, and combination of flat slab-column system at home and abroad to the lack of relevant test for composite flat beams and the design and calculation method of combination of flat slab floor are limited, and no combination design method of flat slab floor can refer to. The ANSYS finite element program is used to predict the results of the experiment. The finite element calculation process and the results are briefly introduced in the following examples: the 300 x 300 by 12 column model:
5.1 finite element model
Using ANSYS finite element program established the combination of single and double flat slab-column system whole model, and the action of vertical load and horizontal load, and applying level step by step, the floor under the vertical load bearing performance analysis. In order to simplify the calculation model, and improve the computational efficiency, under the vertical load according to the hierarchical method of single floor model is established, and the floor vibration performance research has adopted the single floor model; In the study of the performance and spatial performance of floor building, a double floor model was adopted. The finite element model is shown in figure 4 and figure 5.
Figure 4 fem model
FIG. 5 simple fem mode