填充墙(国外英文资料).docVIP

  1. 1、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
填充墙(国外英文资料)

填充墙(国外英文资料) One, material requirement Strictly control the quality of the entry block, including strength, geometry, appearance, etc. 2, block and brick are made before the masonry, water is watered thoroughly one day in advance, the brick wall is strictly prohibited. Second, the requirement of the implant 1, the position of the implant is located in the inverted module method, the first row of steel bar is 30cm, the distance is 50cm, the depth and diameter of the hole must meet the design requirements. The cleaning of the hole shall be used for special electric hair dryer to ensure the cleaning effect of the dust. The masonry can only be built after the tensile test of the wall is qualified. 4, the setting of the structure of the structure shall be arranged strictly according to the requirements of the construction drawing, the length of the longitudinal reinforcement shall meet the design requirements, and the area hoop shall be encrypted in accordance with the requirements. In the case of steel reinforcement, the length of the reinforcement shall be satisfied by the length of the reinforcement bar. Third, other requirements 1, all have strong waterproof requirements of foot room according to the rules require the use of C20 fine stone concrete (200 ㎜ high, wide and wall thickness) for casting, prior to concrete casting, summer-planting parts must be cut hair, and rinse clean with water, must ensure that vibratory compaction when casting; 2, the building materials on the floor should be kept as close to the wall as possible. 3, all prefabricated lintel must be strictly in accordance with codes for design atlas and related production, production after the completion of the ink mark up and down direction, avoid installation process reinforced position reverse; The precast beam requirement is made up 28 days in advance, and the installation must ensure that the strength meets the design requirement. Construction requirements All the walls are made of three-line poro

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档