CT室血管CTA诊断请求及扫描标准(国外英文资料).doc

CT室血管CTA诊断请求及扫描标准(国外英文资料).doc

  1. 1、本文档共10页,可阅读全部内容。
  2. 2、原创力文档(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
CT室血管CTA诊断请求及扫描标准(国外英文资料)

CT室血管CTA诊断要求及扫描标准(国外英文资料) CT angioascular CTA diagnostic requirements and scanning criteria In order to improve the diagnostic requirements of CTA, to prevent the occurrence of accidents, the rules are as follows: Diagnosis, Requires every diagnostician master major arterial anatomy, including intracranial arteries, neck, chest and main branch, the branch of pulmonary artery and aorta, the main branch of coronary artery and the lower limb artery main branches. Every doctor is required to be skilled in the postprocessing software of CTA, especially the posterior treatment of coronary artery CTA. For each patient who does a vasculature, the image must be reconstructed on the workstation, looking at the original image and the reconstructed image. If there is any doubt about the diagnosis, it should be communicated or consulted. In principle, it is necessary to have two doctors above the doctor to report the report, otherwise the consequences will be egotistical. The CTA images should be reviewed by the doctor above the attending physician, and the identification of vulnerable plaques should be looked at in the meantime. Scan standard Every machine operator must be skilled in the use of Smart Prep and Time bouls scanning. It is required that each vessel CTA must be scanned using either of the above methods. All scans use 1.25 or 0.625 mm thick layers, or they can be used to recreate the thick scans. The total dose of contrast agent is adjusted according to the time of scan, the basic principle is that the scanning time is long and the dosage of the contrast agent should be increased accordingly. But not more than 2.5 ml/kg weight. The specific requirements are as follows: 1, the head/CTA CTV Scan the neck of the neck 2 to the head of the skull Recon Type STD Scanning Head Injection of static injection ULT370 / OMP350 Current rate 4.0 to 5.0 ml/s Flow 70ml Delay time CTA: the SmartPrep method, the internal carotid/carotid area of 100HU is triggered manually CTV: Timebou

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档