新《采光顶与金属屋面技术规程》掌握要点(国外英文资料)
新《采光顶与金属屋面技术规程》掌握要点(国外英文资料)
The new lighting roof and metal roof technical regulations holds the key points
Zhou Peijie
Jgj255-2012 the lighting top and metal roof technical regulations has been implemented on October 1, 2012, and the main points to be understood and mastered are:
The applicable scope of this standard
1.1? The panel is the top of the light for materials such as glass and polycarbonate
Metal plate roofing and metal plate roof
Usually contour plate metal roofing can be divided into four classes: vertical side whipstitch roofing system, vertical edge roofing system, Angle and double bite roofing system and greco-roman covered roof system.
Rooftop solar pv system
Set up three mandatory clauses
The heat insulation and insulation materials for the roof and metal roof project are proposed for the insulation and insulation of the metal roof, which shall be made of non-combustible or incombustible materials. It is required to use rock cotton, slag cotton, glass cotton and fire prevention board etc., and its combustion performance should not be lower than B1 level.
2.2 in view of the photovoltaic modules, proposed the photovoltaic modules should be charged warning signs and the corresponding electrical safety protective measures, the personnel may contact or close to the location of the photovoltaic system, should be set against electric shock warning labels. It is.
2.3 in view of the daylighting top and metal roofing thermal performance, put forward have a thermal performance requirements, public buildings on the top of the metal roofing heat transfer coefficient and lighting heat transfer coefficient and shading coefficient shall comply with the provisions of the table below:
Retaining structure
area
Heat transfer coefficient W/(K ㎡.)
Shading coefficient of SC
The coefficient of body mass is less than 0.3
0.3 is less than or less than 0.4
Public buildings
Metal roofing
Cold region area A
0.35 or less
0.30 or less
--
Cold region area B
0.45 or less
0.35 or l