离心泵点检标准(国外英文资料)
离心泵点检标准(国外英文资料)
Inspection standards and methods of centrifugal pump
Inspection area
Check the content
Standards and requirements
Check the method
note
pump
seat
There is no loose or solid ground screw
The ground screw is tightened and filled in
hammer
Is the base level
Adjust the level to the level
visual
al
shaft
device
There is no abnormal sound
There is no severe wear and tear on the wheel, no movement of transmission shaft, no abnormal sound.
Listening to the sounds
The screws are loose
No loose screw
visual
shaft
bearing
with
shaft
Set of
Is the bearing temperature too hot
Sliding bearing temperature 65 ℃;
Rolling bearing temperature 70 ℃.
The instrument
Whether the bearing double peak amplitude exceeds the allowable value
Speed 1800 r/min or less,
The amplitude of the rolling bearing is 0.0762 mm
Sliding bearing amplitude 0.0762 mm
Speed: 1801 ~ 4500 r/min
The amplitude of the rolling bearing is 0.0508 mm
Sliding bearing amplitude 0.0635 mm
The instrument
The bearing is a phenomenon of bending, fraying, crack and erosion
Pump shaft straightness 0.05 mm,
Surface roughness 0.8 um
The instrument
Check if the grinding of the outer ring is too deep
The depth of circular ring on the outer ring of the shaft is no more than 0.5 mm
The instrument
Check to see if the pump shaft is in good condition with the flat key of the impeller and the coupling
Flat key of the two sides should be with the side of the keyway on the pump shaft to realize a small amount of interference fit, but with keyway impeller For transition fit on both sides and coupling hole keyway
The instrument
shaft
seal
loading
buy
Check whether the shaft seal is too tight
When the equipment is running, the bearing is wet and the equipment is not running, and the water drops from 5 to 20 drops per minute.
visual
Check whether the radial clearance between the seal ring and the inlet of the impeller is too large or too small
Between the sealing ring and the outer circle of the impeller, it should be
文档评论(0)